FabDigitFabDigit

Copper Alloy C90800-M02 vs C90800-M07

Copper Alloy · C90800 temper comparison

C90800-M02 and C90800-M07 are two conditions of the same copper alloy grade, C90800: M02 (as centrifugally cast) versus M07 (as continuous cast). The chemistry is identical, so every difference below comes from the condition. C90800-M07 is the stronger of the two: yield strength 180 MPa (26.1 ksi) against 170 MPa (24.7 ksi) for C90800-M02, about 6% more. C90800-M07 is harder — 90 HB against 85 HB for C90800-M02 — which matters for wear surfaces and threads.

C90800-M07Choose it when strength drives the design, or when surface hardness matters.

C90800-M02 vs C90800-M07: properties

C90800-M02C90800-M07

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

330 MPa47.9 ksi
345 MPa50 ksi

Yield Strength (0.2% offset)

170 MPa24.7 ksi
180 MPa26.1 ksi

Reduction in Area

7%
8%

Compressive Strength

450 MPa65.3 ksi
470 MPa68.2 ksi

Shear Strength

230 MPa33.4 ksi
240 MPa34.8 ksi

Fatigue Strength (Endurance Limit)

110 MPa16 ksi
115 MPa16.7 ksi

Charpy V-Notch Impact (RT)

8 J5.9 ft·lbf
9 J6.6 ft·lbf

Hardness, Brinell

85 HB
90 HB

Hardness, Rockwell B

48 HRB
52 HRB

Hardness, Vickers

89 HV
94 HV

Same in both: Elastic (Young's) Modulus 103 GPa14.9 Msi · Shear Modulus 38 GPa5.5 Msi · Bulk Modulus 108 GPa15.7 Msi · Poisson's Ratio 0.34 · Elongation at Break 6%

Physical

Density and transition temperatures.

Same in both: Density 8.8 g/cm³0.32 lb/in³ · Melting Point (Solidus) 854°C1,569 °F · Liquidus Temperature 1,000°C1,832 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 47 W/m·K27.2 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18 µm/m·K10 µin/in·°F · Latent Heat of Fusion 180 J/g77.4 BTU/lb · Max Service Temperature (continuous) 260°C500 °F · Min Service Temperature -100°C-148 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10.5 % IACS · Electrical Resistivity 1.64×10⁻⁷ Ω·m6.46 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V · Corrosion Resistance 70 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Same in both: Machinability 30 / 100 · Machinability Rating (AISI 1212 = 100 %) 20% · Weldability 20 / 100 · Formability (cold) 8 / 100 · Castability 68 / 100 · Brazeability / Solderability 70 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 62 MJ/kg26,655 BTU/lb · Embodied Carbon (primary production) 4.6 kg CO₂/kg · Embodied Water 260 L/kg31.2 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC90800

C90800-M02 vs C90800-M07 — frequently asked

Is C90800-M07 stronger than C90800-M02?

Yes. C90800-M07 has a typical yield strength of 180 MPa (26.1 ksi) against 170 MPa (24.7 ksi) for C90800-M02 — about 6% more. Tensile strength is 345 MPa (50 ksi) vs 330 MPa (47.9 ksi).

Which condition does FabDigit quote by default, M02 or M07?

M01 is the default C90800 condition in the FabDigit quote flow (neither M02 nor M07). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C90800-M02 over C90800-M07?

Pick C90800-M07 when strength drives the design, or when surface hardness matters.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C90800-M02 and C90800-M07 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.