FabDigitFabDigit

Copper Alloy C90700-M01 vs C90700-M02

Copper Alloy · C90700 temper comparison

C90700-M01 and C90700-M02 are two conditions of the same copper alloy grade, C90700: M01 (as sand cast) versus M02 (as centrifugally cast). The chemistry is identical, so every difference below comes from the condition. C90700-M02 is the stronger of the two: yield strength 175 MPa (25.4 ksi) against 152 MPa (22 ksi) for C90700-M01, about 15% more; tensile strength follows at 330 MPa (47.9 ksi) vs 305 MPa (44.2 ksi). C90700-M02 is harder — 90 HB against 80 HB for C90700-M01 — which matters for wear surfaces and threads.

C90700-M02Choose it when strength drives the design, or when surface hardness matters.

C90700-M01 vs C90700-M02: properties

C90700-M01C90700-M02

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

305 MPa44.2 ksi
330 MPa47.9 ksi

Yield Strength (0.2% offset)

152 MPa22 ksi
175 MPa25.4 ksi

Elongation at Break

12%
11%

Reduction in Area

12%
13%

Compressive Strength

420 MPa60.9 ksi
440 MPa63.8 ksi

Shear Strength

205 MPa29.7 ksi
220 MPa31.9 ksi

Fatigue Strength (Endurance Limit)

105 MPa15.2 ksi
110 MPa16 ksi

Charpy V-Notch Impact (RT)

10 J7.4 ft·lbf
11 J8.1 ft·lbf

Hardness, Brinell

80 HB
90 HB

Hardness, Rockwell B

41 HRB
50 HRB

Hardness, Vickers

85 HV
95 HV

Same in both: Elastic (Young's) Modulus 110 GPa16 Msi · Shear Modulus 41 GPa5.9 Msi · Bulk Modulus 115 GPa16.7 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.77 g/cm³0.32 lb/in³ · Melting Point (Solidus) 830°C1,526 °F · Liquidus Temperature 1,000°C1,832 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 50 W/m·K28.9 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18.4 µm/m·K10.2 µin/in·°F · Latent Heat of Fusion 170 J/g73.1 BTU/lb · Max Service Temperature (continuous) 250°C482 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10.9 % IACS · Electrical Resistivity 1.58×10⁻⁷ Ω·m6.22 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

65 / 100
66 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.31 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Same in both: Machinability 45 / 100 · Machinability Rating (AISI 1212 = 100 %) 60% · Weldability 25 / 100 · Formability (cold) 10 / 100 · Castability 80 / 100 · Brazeability / Solderability 85 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 62 MJ/kg26,655 BTU/lb · Embodied Carbon (primary production) 4.5 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 45%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC90700

C90700-M01 vs C90700-M02 — frequently asked

Is C90700-M02 stronger than C90700-M01?

Yes. C90700-M02 has a typical yield strength of 175 MPa (25.4 ksi) against 152 MPa (22 ksi) for C90700-M01 — about 15% more. Tensile strength is 330 MPa (47.9 ksi) vs 305 MPa (44.2 ksi).

Which condition does FabDigit quote by default, M01 or M02?

M01 is the default C90700 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C90700-M01 over C90700-M02?

Pick C90700-M02 when strength drives the design, or when surface hardness matters.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C90700-M01 and C90700-M02 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.