FabDigitFabDigit

Copper Alloy C90500-M01 vs C90500-M05

Copper Alloy · C90500 temper comparison

C90500-M01 and C90500-M05 are two conditions of the same copper alloy grade, C90500: M01 (as sand cast) versus M05 (as plaster cast). The chemistry is identical, so every difference below comes from the condition. C90500-M05 is the stronger of the two: yield strength 172 MPa (24.9 ksi) against 152 MPa (22 ksi) for C90500-M01, about 13% more; tensile strength follows at 331 MPa (48 ksi) vs 310 MPa (45 ksi). In exchange, C90500-M01 is the more ductile: elongation 25% versus 18% for C90500-M05, and C90500-M05 is harder (82 HB vs 75 HB).

C90500-M01Choose it when the part is bent, formed or impact-loaded.

C90500-M05Choose it when strength drives the design.

C90500-M01 vs C90500-M05: properties

C90500-M01C90500-M05

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

310 MPa45 ksi
331 MPa48 ksi

Yield Strength (0.2% offset)

152 MPa22 ksi
172 MPa24.9 ksi

Elongation at Break

25%
18%

Shear Strength

205 MPa29.7 ksi
215 MPa31.2 ksi

Fatigue Strength (Endurance Limit)

100 MPa14.5 ksi
110 MPa16 ksi

Charpy V-Notch Impact (RT)

14 J10.3 ft·lbf
10 J7.4 ft·lbf

Hardness, Brinell

75 HB
82 HB

Same in both: Elastic (Young's) Modulus 103 GPa14.9 Msi · Shear Modulus 38 GPa5.5 Msi · Bulk Modulus 110 GPa16 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.72 g/cm³0.32 lb/in³ · Melting Point (Solidus) 854°C1,569 °F · Liquidus Temperature 999°C1,830 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 71 W/m·K41 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18 µm/m·K10 µin/in·°F · Latent Heat of Fusion 170 J/g73.1 BTU/lb · Max Service Temperature (continuous) 260°C500 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 11 % IACS · Electrical Resistivity 1.57×10⁻⁷ Ω·m6.18 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

65 / 100
68 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

35 / 100
34 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 30% · Weldability 30 / 100 · Formability (cold) 10 / 100 · Castability 92 / 100 · Brazeability / Solderability 80 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 58 MJ/kg24,936 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 320 L/kg38.3 gal/lb · Typical Recycled Content 60%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC90500

C90500-M01 vs C90500-M05 — frequently asked

Is C90500-M05 stronger than C90500-M01?

Yes. C90500-M05 has a typical yield strength of 172 MPa (24.9 ksi) against 152 MPa (22 ksi) for C90500-M01 — about 13% more. Tensile strength is 331 MPa (48 ksi) vs 310 MPa (45 ksi).

Which condition does FabDigit quote by default, M01 or M05?

M01 is the default C90500 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C90500-M01 over C90500-M05?

Pick C90500-M01 when the part is bent, formed or impact-loaded. Pick C90500-M05 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C90500-M01 and C90500-M05 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.