FabDigitFabDigit

Copper Alloy C90200-M01 vs C90200-M02

Copper Alloy · C90200 temper comparison

C90200-M01 and C90200-M02 are two conditions of the same copper alloy grade, C90200: M01 (as sand cast) versus M02 (as centrifugally cast). The chemistry is identical, so every difference below comes from the condition. C90200-M02 is the stronger of the two: yield strength 138 MPa (20 ksi) against 124 MPa (18 ksi) for C90200-M01, about 11% more; tensile strength follows at 300 MPa (43.5 ksi) vs 276 MPa (40 ksi). In exchange, C90200-M01 is the more ductile: elongation 30% versus 25% for C90200-M02, and C90200-M02 is harder (65 HB vs 60 HB).

C90200-M01Choose it when the part is bent, formed or impact-loaded.

C90200-M02Choose it when strength drives the design.

C90200-M01 vs C90200-M02: properties

C90200-M01C90200-M02

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

100 GPa14.5 Msi
103 GPa14.9 Msi

Tensile Strength (Ultimate)

276 MPa40 ksi
300 MPa43.5 ksi

Yield Strength (0.2% offset)

124 MPa18 ksi
138 MPa20 ksi

Elongation at Break

30%
25%

Reduction in Area

28%
24%

Compressive Strength

240 MPa34.8 ksi
260 MPa37.7 ksi

Shear Strength

200 MPa29 ksi
215 MPa31.2 ksi

Fatigue Strength (Endurance Limit)

90 MPa13.1 ksi
100 MPa14.5 ksi

Charpy V-Notch Impact (RT)

20 J14.8 ft·lbf
18 J13.3 ft·lbf

Hardness, Brinell

60 HB
65 HB

Hardness, Rockwell B

25 HRB
32 HRB

Hardness, Vickers

63 HV
68 HV

Same in both: Shear Modulus 38 GPa5.5 Msi · Bulk Modulus 110 GPa16 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.72 g/cm³0.32 lb/in³ · Melting Point (Solidus) 855°C1,571 °F · Liquidus Temperature 1,000°C1,832 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 71 W/m·K41 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18 µm/m·K10 µin/in·°F · Latent Heat of Fusion 190 J/g81.7 BTU/lb · Max Service Temperature (continuous) 230°C446 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 14 % IACS · Electrical Resistivity 1.23×10⁻⁷ Ω·m4.84 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

72 / 100
73 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Same in both: Machinability 32 / 100 · Machinability Rating (AISI 1212 = 100 %) 30% · Weldability 45 / 100 · Formability (cold) 10 / 100 · Castability 70 / 100 · Brazeability / Solderability 85 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 70%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC90200

C90200-M01 vs C90200-M02 — frequently asked

Is C90200-M02 stronger than C90200-M01?

Yes. C90200-M02 has a typical yield strength of 138 MPa (20 ksi) against 124 MPa (18 ksi) for C90200-M01 — about 11% more. Tensile strength is 300 MPa (43.5 ksi) vs 276 MPa (40 ksi).

Which condition does FabDigit quote by default, M01 or M02?

M01 is the default C90200 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C90200-M01 over C90200-M02?

Pick C90200-M01 when the part is bent, formed or impact-loaded. Pick C90200-M02 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C90200-M01 and C90200-M02 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.