FabDigitFabDigit

Copper Alloy C89320-M01 vs C89320-M04

Copper Alloy · C89320 temper comparison

C89320-M01 and C89320-M04 are two conditions of the same copper alloy grade, C89320: M01 (as sand cast) versus M04 (as pressure die cast). The chemistry is identical, so every difference below comes from the condition. C89320-M04 is the stronger of the two: yield strength 131 MPa (19 ksi) against 117 MPa (17 ksi) for C89320-M01, about 12% more; tensile strength follows at 255 MPa (37 ksi) vs 241 MPa (35 ksi). C89320-M04 is harder — 65 HB against 60 HB for C89320-M01 — which matters for wear surfaces and threads.

C89320-M04Choose it when strength drives the design, or when surface hardness matters.

C89320-M01 vs C89320-M04: properties

C89320-M01C89320-M04

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

241 MPa35 ksi
255 MPa37 ksi

Yield Strength (0.2% offset)

117 MPa17 ksi
131 MPa19 ksi

Elongation at Break

15%
14%

Reduction in Area

18%
17%

Shear Strength

170 MPa24.7 ksi
180 MPa26.1 ksi

Fatigue Strength (Endurance Limit)

90 MPa13.1 ksi
95 MPa13.8 ksi

Charpy V-Notch Impact (RT)

14 J10.3 ft·lbf
13 J9.6 ft·lbf

Hardness, Brinell

60 HB
65 HB

Hardness, Rockwell B

25 HRB
30 HRB

Hardness, Vickers

63 HV
68 HV

Same in both: Elastic (Young's) Modulus 100 GPa14.5 Msi · Shear Modulus 37 GPa5.4 Msi · Bulk Modulus 104 GPa15.1 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.6 g/cm³0.31 lb/in³ · Melting Point (Solidus) 854°C1,569 °F · Liquidus Temperature 1,000°C1,832 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 60 W/m·K34.7 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18.4 µm/m·K10.2 µin/in·°F · Latent Heat of Fusion 170 J/g73.1 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -100°C-148 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 12 % IACS · Electrical Resistivity 1.44×10⁻⁷ Ω·m5.67 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V · Corrosion Resistance 70 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Formability (cold)

15 / 100
14 / 100

Same in both: Machinability 80 / 100 · Machinability Rating (AISI 1212 = 100 %) 80% · Weldability 30 / 100 · Castability 85 / 100 · Brazeability / Solderability 55 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 55%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC89320

C89320-M01 vs C89320-M04 — frequently asked

Is C89320-M04 stronger than C89320-M01?

Yes. C89320-M04 has a typical yield strength of 131 MPa (19 ksi) against 117 MPa (17 ksi) for C89320-M01 — about 12% more. Tensile strength is 255 MPa (37 ksi) vs 241 MPa (35 ksi).

Which condition does FabDigit quote by default, M01 or M04?

M01 is the default C89320 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C89320-M01 over C89320-M04?

Pick C89320-M04 when strength drives the design, or when surface hardness matters.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C89320-M01 and C89320-M04 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.