FabDigitFabDigit

Copper Alloy C87300-M02 vs C87300-M07

Copper Alloy · C87300 temper comparison

C87300-M02 and C87300-M07 are two conditions of the same copper alloy grade, C87300: M02 (as centrifugally cast) versus M07 (as continuous cast). The chemistry is identical, so every difference below comes from the condition. C87300-M07 is the stronger of the two: yield strength 235 MPa (34.1 ksi) against 220 MPa (31.9 ksi) for C87300-M02, about 7% more. In exchange, C87300-M02 is the more ductile: elongation 27% versus 24% for C87300-M07, and C87300-M07 is harder (95 HB vs 90 HB).

C87300-M02Choose it when the part is bent, formed or impact-loaded.

C87300-M07Choose it when strength drives the design.

C87300-M02 vs C87300-M07: properties

C87300-M02C87300-M07

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

415 MPa60.2 ksi
425 MPa61.6 ksi

Yield Strength (0.2% offset)

220 MPa31.9 ksi
235 MPa34.1 ksi

Elongation at Break

27%
24%

Shear Strength

270 MPa39.2 ksi
278 MPa40.3 ksi

Fatigue Strength (Endurance Limit)

140 MPa20.3 ksi
145 MPa21 ksi

Charpy V-Notch Impact (RT)

45 J33.2 ft·lbf
36 J26.6 ft·lbf

Hardness, Brinell

90 HB
95 HB

Same in both: Elastic (Young's) Modulus 103 GPa14.9 Msi · Shear Modulus 39 GPa5.7 Msi · Bulk Modulus 105 GPa15.2 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.3 g/cm³0.3 lb/in³ · Melting Point (Solidus) 917°C1,683 °F · Liquidus Temperature 1,010°C1,850 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

29 W/m·K16.8 BTU/hr·ft·°F
30 W/m·K17.3 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 376 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18 µm/m·K10 µin/in·°F · Latent Heat of Fusion 210 J/g90.3 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

6.7 % IACS
7 % IACS

Electrical Resistivity

2.6×10⁻⁷ Ω·m10.2 µΩ·in
2.5×10⁻⁷ Ω·m9.84 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

75 / 100
76 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.26 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

40 / 100
42 / 100

Machinability Rating (AISI 1212 = 100 %)

50%
52%

Formability (cold)

20 / 100
22 / 100

Same in both: Weldability 92 / 100 · Castability 85 / 100 · Brazeability / Solderability 75 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 220 L/kg26.4 gal/lb · Typical Recycled Content 75%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC87300

C87300-M02 vs C87300-M07 — frequently asked

Is C87300-M07 stronger than C87300-M02?

Yes. C87300-M07 has a typical yield strength of 235 MPa (34.1 ksi) against 220 MPa (31.9 ksi) for C87300-M02 — about 7% more. Tensile strength is 425 MPa (61.6 ksi) vs 415 MPa (60.2 ksi).

Which condition does FabDigit quote by default, M02 or M07?

M01 is the default C87300 condition in the FabDigit quote flow (neither M02 nor M07). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C87300-M02 over C87300-M07?

Pick C87300-M02 when the part is bent, formed or impact-loaded. Pick C87300-M07 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C87300-M02 and C87300-M07 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.