FabDigitFabDigit

Copper Alloy C87300-M01 vs C87300-M05

Copper Alloy · C87300 temper comparison

C87300-M01 and C87300-M05 are two conditions of the same copper alloy grade, C87300: M01 (as sand cast) versus M05 (as plaster cast). The chemistry is identical, so every difference below comes from the condition. C87300-M05 is the stronger of the two: yield strength 215 MPa (31.2 ksi) against 200 MPa (29 ksi) for C87300-M01, about 8% more; tensile strength follows at 410 MPa (59.5 ksi) vs 379 MPa (55 ksi). C87300-M05 is harder — 90 HB against 85 HB for C87300-M01 — which matters for wear surfaces and threads. On the shop floor, C87300-M01 forms better (fair vs poor).

C87300-M05Choose it when strength drives the design, or when surface hardness matters.

C87300-M01 vs C87300-M05: properties

C87300-M01C87300-M05

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

379 MPa55 ksi
410 MPa59.5 ksi

Yield Strength (0.2% offset)

200 MPa29 ksi
215 MPa31.2 ksi

Elongation at Break

30%
28%

Shear Strength

250 MPa36.3 ksi
265 MPa38.4 ksi

Fatigue Strength (Endurance Limit)

130 MPa18.9 ksi
138 MPa20 ksi

Charpy V-Notch Impact (RT)

40 J29.5 ft·lbf
42 J31 ft·lbf

Hardness, Brinell

85 HB
90 HB

Same in both: Elastic (Young's) Modulus 103 GPa14.9 Msi · Shear Modulus 39 GPa5.7 Msi · Bulk Modulus 105 GPa15.2 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.3 g/cm³0.3 lb/in³ · Melting Point (Solidus) 917°C1,683 °F · Liquidus Temperature 1,010°C1,850 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 29 W/m·K16.8 BTU/hr·ft·°F · Specific Heat Capacity 376 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18 µm/m·K10 µin/in·°F · Latent Heat of Fusion 210 J/g90.3 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 6.7 % IACS · Electrical Resistivity 2.6×10⁻⁷ Ω·m10.2 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

74 / 100
75 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.26 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Formability (cold)

35 / 100
20 / 100

Same in both: Machinability 40 / 100 · Machinability Rating (AISI 1212 = 100 %) 50% · Weldability 92 / 100 · Castability 85 / 100 · Brazeability / Solderability 75 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 220 L/kg26.4 gal/lb · Typical Recycled Content 75%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC87300

C87300-M01 vs C87300-M05 — frequently asked

Is C87300-M05 stronger than C87300-M01?

Yes. C87300-M05 has a typical yield strength of 215 MPa (31.2 ksi) against 200 MPa (29 ksi) for C87300-M01 — about 8% more. Tensile strength is 410 MPa (59.5 ksi) vs 379 MPa (55 ksi).

Which condition does FabDigit quote by default, M01 or M05?

M01 is the default C87300 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C87300-M01 over C87300-M05?

Pick C87300-M05 when strength drives the design, or when surface hardness matters.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C87300-M01 and C87300-M05 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.