FabDigitFabDigit

Copper Alloy C85700-M02 vs C85700-M05

Copper Alloy · C85700 temper comparison

C85700-M02 and C85700-M05 are two conditions of the same copper alloy grade, C85700: M02 (as centrifugally cast) versus M05 (as plaster cast). The chemistry is identical, so every difference below comes from the condition. C85700-M05 is the stronger of the two: yield strength 170 MPa (24.7 ksi) against 160 MPa (23.2 ksi) for C85700-M02, about 6% more. C85700-M05 is harder — 85 HB against 80 HB for C85700-M02 — which matters for wear surfaces and threads.

C85700-M05Choose it when strength drives the design, or when surface hardness matters.

C85700-M02 vs C85700-M05: properties

C85700-M02C85700-M05

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

400 MPa58 ksi
415 MPa60.2 ksi

Yield Strength (0.2% offset)

160 MPa23.2 ksi
170 MPa24.7 ksi

Elongation at Break

16%
15%

Shear Strength

250 MPa36.3 ksi
260 MPa37.7 ksi

Fatigue Strength (Endurance Limit)

110 MPa16 ksi
115 MPa16.7 ksi

Charpy V-Notch Impact (RT)

13 J9.6 ft·lbf
12 J8.9 ft·lbf

Hardness, Brinell

80 HB
85 HB

Same in both: Elastic (Young's) Modulus 100 GPa14.5 Msi · Shear Modulus 37 GPa5.4 Msi · Bulk Modulus 105 GPa15.2 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.41 g/cm³0.3 lb/in³ · Melting Point (Solidus) 875°C1,607 °F · Liquidus Temperature 905°C1,661 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 84 W/m·K48.5 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21.6 µm/m·K12 µin/in·°F · Latent Heat of Fusion 165 J/g70.9 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 22 % IACS · Electrical Resistivity 7.8×10⁻⁸ Ω·m3.07 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.3 V · Corrosion Resistance 45 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Same in both: Machinability 80 / 100 · Weldability 20 / 100 · Castability 80 / 100 · Brazeability / Solderability 75 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 60 MJ/kg25,795 BTU/lb · Embodied Carbon (primary production) 4 kg CO₂/kg · Embodied Water 320 L/kg38.3 gal/lb · Typical Recycled Content 90%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC85700

C85700-M02 vs C85700-M05 — frequently asked

Is C85700-M05 stronger than C85700-M02?

Yes. C85700-M05 has a typical yield strength of 170 MPa (24.7 ksi) against 160 MPa (23.2 ksi) for C85700-M02 — about 6% more. Tensile strength is 415 MPa (60.2 ksi) vs 400 MPa (58 ksi).

Which condition does FabDigit quote by default, M02 or M05?

M01 is the default C85700 condition in the FabDigit quote flow (neither M02 nor M05). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C85700-M02 over C85700-M05?

Pick C85700-M05 when strength drives the design, or when surface hardness matters.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C85700-M02 and C85700-M05 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.