C83800-M02 and C83800-M07 are two conditions of the same copper alloy grade, C83800: M02 (as centrifugally cast) versus M07 (as continuous cast). The chemistry is identical, so every difference below comes from the condition. C83800-M07 is the stronger of the two: yield strength 138 MPa (20 ksi) against 117 MPa (17 ksi) for C83800-M02, about 18% more. In exchange, C83800-M02 is the more ductile: elongation 22% versus 16% for C83800-M07, and C83800-M07 is harder (65 HB vs 60 HB).

C83800-M02Choose it when the part is bent, formed or impact-loaded.

C83800-M07Choose it when strength drives the design.

C83800-M02 vs C83800-M07: properties

C83800-M02C83800-M07

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

255 MPa37 ksi
262 MPa38 ksi

Yield Strength (0.2% offset)

117 MPa17 ksi
138 MPa20 ksi

Elongation at Break

22%
16%

Compressive Strength

245 MPa35.5 ksi
255 MPa37 ksi

Shear Strength

203 MPa29.4 ksi
207 MPa30 ksi

Fatigue Strength (Endurance Limit)

79 MPa11.5 ksi
83 MPa12 ksi

Hardness, Brinell

60 HB
65 HB

Same in both: Elastic (Young's) Modulus 90 GPa13.1 Msi · Shear Modulus 34 GPa4.9 Msi · Bulk Modulus 95 GPa13.8 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.6 g/cm³0.31 lb/in³ · Melting Point (Solidus) 843°C1,549 °F · Liquidus Temperature 1,004°C1,839 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 72 W/m·K41.6 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18 µm/m·K10 µin/in·°F · Latent Heat of Fusion 175 J/g75.2 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -100°C-148 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 15 % IACS · Electrical Resistivity 1.15×10⁻⁷ Ω·m4.53 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

59 / 100
60 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

88 / 100
90 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 90% · Weldability 20 / 100 · Castability 88 / 100 · Brazeability / Solderability 80 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 85%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC83800

C83800-M02 vs C83800-M07 — frequently asked

Is C83800-M07 stronger than C83800-M02?

Yes. C83800-M07 has a typical yield strength of 138 MPa (20 ksi) against 117 MPa (17 ksi) for C83800-M02 — about 18% more. Tensile strength is 262 MPa (38 ksi) vs 255 MPa (37 ksi).

Which condition does FabDigit quote by default, M02 or M07?

M01 is the default C83800 condition in the FabDigit quote flow (neither M02 nor M07). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C83800-M02 over C83800-M07?

Pick C83800-M02 when the part is bent, formed or impact-loaded. Pick C83800-M07 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C83800-M02 and C83800-M07 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.