Copper Alloy C82000-TB00 vs C82000-TF00
Copper Alloy · C82000 temper comparison
C82000-TB00 and C82000-TF00 are two conditions of the same copper alloy grade, C82000: TB00 (solution heat treated) versus TF00 (solution heat treated and precipitation hardened). The chemistry is identical, so every difference below comes from the condition. C82000-TF00 is the stronger of the two: yield strength 500 MPa (72.5 ksi) against 140 MPa (20.3 ksi) for C82000-TB00, about 3.6 times as much; tensile strength follows at 655 MPa (95 ksi) vs 290 MPa (42.1 ksi). In exchange, C82000-TB00 is the more ductile: elongation 25% versus 5% for C82000-TF00, and C82000-TF00 is harder (210 HB vs 85 HB). C82000-TF00 runs hotter in service (230°C vs 150°C continuous) and C82000-TF00 conducts heat better (190 W/m·K vs 90 W/m·K). On the shop floor, C82000-TB00 machines more easily (fair vs poor).
C82000-TB00Choose it when the part is bent, formed or impact-loaded, or when the part is machined in volume.
C82000-TF00Choose it when strength drives the design, or when the part sees heat.
C82000-TB00 vs C82000-TF00: propertiesHow to read these bars
- One bar per material. A full bar is the highest value among all copper alloy grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
How to read these bars
- One bar per material. A full bar is the highest value among all copper alloy grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
Mechanical
Strength, stiffness, ductility and hardness at room temperature.
Tensile Strength (Ultimate)
Yield Strength (0.2% offset)
Elongation at Break
Hardness, Brinell
Hardness, Rockwell B
Same in both: Elastic (Young's) Modulus 138 GPa20 Msi · Shear Modulus 53 GPa7.7 Msi · Bulk Modulus 115 GPa16.7 Msi · Poisson's Ratio 0.3 · Compressive Strength 520 MPa75.4 ksi · Shear Strength 440 MPa63.8 ksi · Fatigue Strength (Endurance Limit) 185 MPa26.8 ksi · Charpy V-Notch Impact (RT) 11 J8.1 ft·lbf · Hardness, Rockwell C 22 HRC
Physical
Density and transition temperatures.
Same in both: Density 8.61 g/cm³0.31 lb/in³ · Melting Point (Solidus) 1,038°C1,900 °F · Liquidus Temperature 1,068°C1,954 °F
Thermal
How each material carries heat and how hot it can run.
Thermal Conductivity
Max Service Temperature (continuous)
Same in both: Specific Heat Capacity 419 J/kg·K0.1 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.8 µm/m·K9.9 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -200°C-328 °F
Electrical
Conductivity and insulation.
Electrical Conductivity
Electrical Resistivity
Chemical & Environmental
Corrosion and environmental resistance (0–100 scores).
Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V · Corrosion Resistance 65 / 100
Manufacturability
FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.
Machinability
Formability (cold)
Same in both: Machinability Rating (AISI 1212 = 100 %) 20% · Weldability 40 / 100 · Castability 75 / 100 · Brazeability / Solderability 60 / 100 · Polishability 80 / 100
Sustainability
Primary-production footprint per kilogram.
Same in both: Embodied Energy (primary production) 95 MJ/kg40,843 BTU/lb · Embodied Carbon (primary production) 6.5 kg CO₂/kg · Embodied Water 350 L/kg41.9 gal/lb · Typical Recycled Content 30%
Strength versus weight
Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.
C82000-TB00 vs C82000-TF00 — frequently asked
Is C82000-TF00 stronger than C82000-TB00?
Yes. C82000-TF00 has a typical yield strength of 500 MPa (72.5 ksi) against 140 MPa (20.3 ksi) for C82000-TB00 — about 3.6 times as much. Tensile strength is 655 MPa (95 ksi) vs 290 MPa (42.1 ksi).
Which condition does FabDigit quote by default, TB00 or TF00?
TF00 is the default C82000 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.
Which is easier to machine, C82000-TB00 or C82000-TF00?
C82000-TB00. Its machinability rates fair (35/100) against poor (25/100) for C82000-TF00.
Ready to make it?
Upload a CAD file and FabDigit prices the part in C82000-TB00 and C82000-TF00 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.
Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.