FabDigitFabDigit

Copper Alloy C81700-TB00 vs C81700-TF00

Copper Alloy · C81700 temper comparison

C81700-TB00 and C81700-TF00 are two conditions of the same copper alloy grade, C81700: TB00 (solution heat treated) versus TF00 (solution heat treated and precipitation hardened). The chemistry is identical, so every difference below comes from the condition. C81700-TF00 is the stronger of the two: yield strength 515 MPa (74.7 ksi) against 125 MPa (18.1 ksi) for C81700-TB00, about 4.1 times as much; tensile strength follows at 655 MPa (95 ksi) vs 330 MPa (47.9 ksi). In exchange, C81700-TB00 is the more ductile: elongation 25% versus 5% for C81700-TF00, and C81700-TF00 is harder (200 HB vs 70 HB). C81700-TF00 conducts heat better (190 W/m·K vs 120 W/m·K).

C81700-TB00Choose it when the part is bent, formed or impact-loaded.

C81700-TF00Choose it when strength drives the design.

C81700-TB00 vs C81700-TF00: properties

C81700-TB00C81700-TF00

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

330 MPa47.9 ksi
655 MPa95 ksi

Yield Strength (0.2% offset)

125 MPa18.1 ksi
515 MPa74.7 ksi

Elongation at Break

25%
5%

Hardness, Brinell

70 HB
200 HB

Hardness, Rockwell B

35 HRB
96 HRB

Same in both: Elastic (Young's) Modulus 130 GPa18.9 Msi · Shear Modulus 50 GPa7.3 Msi · Bulk Modulus 120 GPa17.4 Msi · Poisson's Ratio 0.3 · Shear Strength 420 MPa60.9 ksi · Fatigue Strength (Endurance Limit) 240 MPa34.8 ksi · Hardness, Rockwell C 20 HRC

Physical

Density and transition temperatures.

Same in both: Density 8.75 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,030°C1,886 °F · Liquidus Temperature 1,070°C1,958 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

120 W/m·K69.3 BTU/hr·ft·°F
190 W/m·K110 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 420 J/kg·K0.1 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.5 µm/m·K9.7 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

25 % IACS
45 % IACS

Electrical Resistivity

6.9×10⁻⁸ Ω·m2.72 µΩ·in
3.8×10⁻⁸ Ω·m1.5 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.2 V · Corrosion Resistance 65 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability Rating (AISI 1212 = 100 %)

25%
20%

Same in both: Machinability 45 / 100 · Weldability 45 / 100 · Castability 80 / 100 · Brazeability / Solderability 60 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 70 MJ/kg30,095 BTU/lb · Embodied Carbon (primary production) 4.5 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC81700

C81700-TB00 vs C81700-TF00 — frequently asked

Is C81700-TF00 stronger than C81700-TB00?

Yes. C81700-TF00 has a typical yield strength of 515 MPa (74.7 ksi) against 125 MPa (18.1 ksi) for C81700-TB00 — about 4.1 times as much. Tensile strength is 655 MPa (95 ksi) vs 330 MPa (47.9 ksi).

Which condition does FabDigit quote by default, TB00 or TF00?

TF00 is the default C81700 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C81700-TB00 over C81700-TF00?

Pick C81700-TB00 when the part is bent, formed or impact-loaded. Pick C81700-TF00 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C81700-TB00 and C81700-TF00 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.