FabDigitFabDigit

Copper Alloy C81200-M02 vs C81200-M07

Copper Alloy · C81200 temper comparison

C81200-M02 and C81200-M07 are two conditions of the same copper alloy grade, C81200: M02 (as centrifugally cast) versus M07 (as continuous cast). The chemistry is identical, so every difference below comes from the condition. C81200-M07 is the stronger of the two: yield strength 75 MPa (10.9 ksi) against 65 MPa (9.43 ksi) for C81200-M02, about 15% more; tensile strength follows at 200 MPa (29 ksi) vs 185 MPa (26.8 ksi). In exchange, C81200-M02 is the more ductile: elongation 40% versus 35% for C81200-M07, and C81200-M07 is harder (50 HB vs 46 HB).

C81200-M02Choose it when the part is bent, formed or impact-loaded.

C81200-M07Choose it when strength drives the design.

C81200-M02 vs C81200-M07: properties

C81200-M02C81200-M07

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

185 MPa26.8 ksi
200 MPa29 ksi

Yield Strength (0.2% offset)

65 MPa9.4 ksi
75 MPa10.9 ksi

Elongation at Break

40%
35%

Reduction in Area

38%
30%

Shear Strength

133 MPa19.3 ksi
145 MPa21 ksi

Fatigue Strength (Endurance Limit)

66 MPa9.6 ksi
72 MPa10.4 ksi

Charpy V-Notch Impact (RT)

50 J36.9 ft·lbf
40 J29.5 ft·lbf

Hardness, Brinell

46 HB
50 HB

Hardness, Vickers

48 HV
52 HV

Same in both: Elastic (Young's) Modulus 112 GPa16.2 Msi · Shear Modulus 42 GPa6.1 Msi · Bulk Modulus 138 GPa20 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.91 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,065°C1,949 °F · Liquidus Temperature 1,083°C1,981 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 325 W/m·K188 BTU/hr·ft·°F · Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.6 µm/m·K9.8 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 82 % IACS · Electrical Resistivity 2.1×10⁻⁸ Ω·m0.827 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.2 V · Corrosion Resistance 65 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Same in both: Machinability 25 / 100 · Machinability Rating (AISI 1212 = 100 %) 20% · Weldability 65 / 100 · Formability (cold) 30 / 100 · Castability 60 / 100 · Brazeability / Solderability 90 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 50%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC81200

C81200-M02 vs C81200-M07 — frequently asked

Is C81200-M07 stronger than C81200-M02?

Yes. C81200-M07 has a typical yield strength of 75 MPa (10.9 ksi) against 65 MPa (9.43 ksi) for C81200-M02 — about 15% more. Tensile strength is 200 MPa (29 ksi) vs 185 MPa (26.8 ksi).

Which condition does FabDigit quote by default, M02 or M07?

M01 is the default C81200 condition in the FabDigit quote flow (neither M02 nor M07). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C81200-M02 over C81200-M07?

Pick C81200-M02 when the part is bent, formed or impact-loaded. Pick C81200-M07 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C81200-M02 and C81200-M07 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.