FabDigitFabDigit

Copper Alloy C80900-M01 vs C80900-M02

Copper Alloy · C80900 temper comparison

C80900-M01 and C80900-M02 are two conditions of the same copper alloy grade, C80900: M01 (as sand cast) versus M02 (as centrifugally cast). The chemistry is identical, so every difference below comes from the condition. C80900-M02 is the stronger of the two: yield strength 70 MPa (10.2 ksi) against 62 MPa (8.99 ksi) for C80900-M01, about 13% more; tensile strength follows at 190 MPa (27.6 ksi) vs 172 MPa (24.9 ksi). In exchange, C80900-M01 is the more ductile: elongation 40% versus 35% for C80900-M02, and C80900-M02 is harder (48 HB vs 44 HB).

C80900-M01Choose it when the part is bent, formed or impact-loaded.

C80900-M02Choose it when strength drives the design.

C80900-M01 vs C80900-M02: properties

C80900-M01C80900-M02

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

115 GPa16.7 Msi
117 GPa17 Msi

Tensile Strength (Ultimate)

172 MPa24.9 ksi
190 MPa27.6 ksi

Yield Strength (0.2% offset)

62 MPa9 ksi
70 MPa10.2 ksi

Elongation at Break

40%
35%

Reduction in Area

45%
40%

Shear Strength

115 MPa16.7 ksi
125 MPa18.1 ksi

Fatigue Strength (Endurance Limit)

60 MPa8.7 ksi
65 MPa9.4 ksi

Charpy V-Notch Impact (RT)

55 J40.6 ft·lbf
50 J36.9 ft·lbf

Hardness, Brinell

44 HB
48 HB

Hardness, Vickers

46 HV
50 HV

Same in both: Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.94 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,065°C1,949 °F · Liquidus Temperature 1,083°C1,981 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 350 W/m·K202 BTU/hr·ft·°F · Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.6 µm/m·K9.8 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 92 % IACS · Electrical Resistivity 1.87×10⁻⁸ Ω·m0.736 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.33 V · Corrosion Resistance 62 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Formability (cold)

35 / 100
38 / 100

Same in both: Machinability 20 / 100 · Machinability Rating (AISI 1212 = 100 %) 20% · Weldability 70 / 100 · Castability 45 / 100 · Brazeability / Solderability 90 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 57 MJ/kg24,506 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC80900

C80900-M01 vs C80900-M02 — frequently asked

Is C80900-M02 stronger than C80900-M01?

Yes. C80900-M02 has a typical yield strength of 70 MPa (10.2 ksi) against 62 MPa (8.99 ksi) for C80900-M01 — about 13% more. Tensile strength is 190 MPa (27.6 ksi) vs 172 MPa (24.9 ksi).

Which condition does FabDigit quote by default, M01 or M02?

M01 is the default C80900 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C80900-M01 over C80900-M02?

Pick C80900-M01 when the part is bent, formed or impact-loaded. Pick C80900-M02 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C80900-M01 and C80900-M02 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.