FabDigitFabDigit

Copper Alloy C79800-H04 vs C79800-M30

Copper Alloy · C79800 temper comparison

C79800-H04 and C79800-M30 are two conditions of the same copper alloy grade, C79800: H04 (full hard) versus M30 (as hot extruded). The chemistry is identical, so every difference below comes from the condition. C79800-H04 is the stronger of the two: yield strength 480 MPa (69.6 ksi) against 200 MPa (29 ksi) for C79800-M30, about 140% more; tensile strength follows at 585 MPa (84.8 ksi) vs 430 MPa (62.4 ksi). In exchange, C79800-M30 is the more ductile: elongation 30% versus 8% for C79800-H04, and C79800-H04 is harder (175 HB vs 110 HB).

C79800-H04Choose it when strength drives the design.

C79800-M30Choose it when the part is bent, formed or impact-loaded.

C79800-H04 vs C79800-M30: properties

C79800-H04C79800-M30

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

585 MPa84.8 ksi
430 MPa62.4 ksi

Yield Strength (0.2% offset)

480 MPa69.6 ksi
200 MPa29 ksi

Elongation at Break

8%
30%

Shear Strength

360 MPa52.2 ksi
290 MPa42.1 ksi

Fatigue Strength (Endurance Limit)

205 MPa29.7 ksi
150 MPa21.8 ksi

Hardness, Brinell

175 HB
110 HB

Hardness, Rockwell B

88 HRB
60 HRB

Hardness, Vickers

185 HV
115 HV

Same in both: Elastic (Young's) Modulus 117 GPa17 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 115 GPa16.7 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 8.69 g/cm³0.31 lb/in³ · Melting Point (Solidus) 890°C1,634 °F · Liquidus Temperature 925°C1,697 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 33 W/m·K19.1 BTU/hr·ft·°F · Specific Heat Capacity 380 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.5 µm/m·K9.2 µin/in·°F · Latent Heat of Fusion 175 J/g75.2 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

7 % IACS
7.5 % IACS

Electrical Resistivity

2.46×10⁻⁷ Ω·m9.69 µΩ·in
2.3×10⁻⁷ Ω·m9.06 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V · Corrosion Resistance 55 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

70 / 100
64 / 100

Machinability Rating (AISI 1212 = 100 %)

60%
56%

Formability (cold)

25 / 100
55 / 100

Same in both: Weldability 15 / 100 · Brazeability / Solderability 65 / 100 · Polishability 85 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 72 MJ/kg30,954 BTU/lb · Embodied Carbon (primary production) 4.8 kg CO₂/kg · Embodied Water 260 L/kg31.2 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC79800

C79800-H04 vs C79800-M30 — frequently asked

Is C79800-H04 stronger than C79800-M30?

Yes. C79800-H04 has a typical yield strength of 480 MPa (69.6 ksi) against 200 MPa (29 ksi) for C79800-M30 — about 140% more. Tensile strength is 585 MPa (84.8 ksi) vs 430 MPa (62.4 ksi).

Which condition does FabDigit quote by default, H04 or M30?

H02 is the default C79800 condition in the FabDigit quote flow (neither H04 nor M30). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C79800-H04 or C79800-M30?

C79800-H04. Its machinability rates very good (70/100) against good (64/100) for C79800-M30.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C79800-H04 and C79800-M30 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.