FabDigitFabDigit

Copper Alloy C79600-H01 vs C79600-M30

Copper Alloy · C79600 temper comparison

C79600-H01 and C79600-M30 are two conditions of the same copper alloy grade, C79600: H01 (quarter hard) versus M30 (as hot extruded). The chemistry is identical, so every difference below comes from the condition. C79600-H01 is the stronger of the two: yield strength 310 MPa (45 ksi) against 210 MPa (30.5 ksi) for C79600-M30, about 48% more; tensile strength follows at 480 MPa (69.6 ksi) vs 450 MPa (65.3 ksi). In exchange, C79600-M30 is the more ductile: elongation 25% versus 22% for C79600-H01, and C79600-H01 is harder (140 HB vs 125 HB). C79600-M30 runs hotter in service (200°C vs 180°C continuous).

C79600-H01Choose it when strength drives the design.

C79600-M30Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C79600-H01 vs C79600-M30: properties

C79600-H01C79600-M30

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

480 MPa69.6 ksi
450 MPa65.3 ksi

Yield Strength (0.2% offset)

310 MPa45 ksi
210 MPa30.5 ksi

Elongation at Break

22%
25%

Shear Strength

320 MPa46.4 ksi
300 MPa43.5 ksi

Fatigue Strength (Endurance Limit)

175 MPa25.4 ksi
160 MPa23.2 ksi

Hardness, Brinell

140 HB
125 HB

Hardness, Rockwell B

78 HRB
70 HRB

Hardness, Vickers

148 HV
130 HV

Same in both: Elastic (Young's) Modulus 117 GPa17 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 115 GPa16.7 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 8.52 g/cm³0.31 lb/in³ · Melting Point (Solidus) 875°C1,607 °F · Liquidus Temperature 925°C1,697 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

180°C356 °F
200°C392 °F

Same in both: Thermal Conductivity 33 W/m·K19.1 BTU/hr·ft·°F · Specific Heat Capacity 380 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18 µm/m·K10 µin/in·°F · Latent Heat of Fusion 175 J/g75.2 BTU/lb · Min Service Temperature -100°C-148 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

8.2 % IACS
8.5 % IACS

Electrical Resistivity

2.1×10⁻⁷ Ω·m8.27 µΩ·in
2.03×10⁻⁷ Ω·m7.99 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V · Corrosion Resistance 55 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

70 / 100
67 / 100

Machinability Rating (AISI 1212 = 100 %)

68%
65%

Formability (cold)

30 / 100
42 / 100

Same in both: Weldability 20 / 100 · Brazeability / Solderability 70 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 62 MJ/kg26,655 BTU/lb · Embodied Carbon (primary production) 4.2 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC79600

C79600-H01 vs C79600-M30 — frequently asked

Is C79600-H01 stronger than C79600-M30?

Yes. C79600-H01 has a typical yield strength of 310 MPa (45 ksi) against 210 MPa (30.5 ksi) for C79600-M30 — about 48% more. Tensile strength is 480 MPa (69.6 ksi) vs 450 MPa (65.3 ksi).

Which condition does FabDigit quote by default, H01 or M30?

H02 is the default C79600 condition in the FabDigit quote flow (neither H01 nor M30). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C79600-H01 over C79600-M30?

Pick C79600-H01 when strength drives the design. Pick C79600-M30 when the part is bent, formed or impact-loaded, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C79600-H01 and C79600-M30 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.