FabDigitFabDigit

Copper Alloy C78200-H02 vs C78200-H03

Copper Alloy · C78200 temper comparison

C78200-H02 and C78200-H03 are two conditions of the same copper alloy grade, C78200: H02 (half hard) versus H03 (three-quarter hard). The chemistry is identical, so every difference below comes from the condition. C78200-H03 is the stronger of the two: yield strength 462 MPa (67 ksi) against 407 MPa (59 ksi) for C78200-H02, about 14% more; tensile strength follows at 524 MPa (76 ksi) vs 483 MPa (70.1 ksi). In exchange, C78200-H02 is the more ductile: elongation 10% versus 6% for C78200-H03, and C78200-H03 is harder (158 HB vs 140 HB).

C78200-H02Choose it when the part is bent, formed or impact-loaded.

C78200-H03Choose it when strength drives the design.

C78200-H02 vs C78200-H03: properties

C78200-H02C78200-H03

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

483 MPa70.1 ksi
524 MPa76 ksi

Yield Strength (0.2% offset)

407 MPa59 ksi
462 MPa67 ksi

Elongation at Break

10%
6%

Shear Strength

330 MPa47.9 ksi
345 MPa50 ksi

Fatigue Strength (Endurance Limit)

175 MPa25.4 ksi
185 MPa26.8 ksi

Hardness, Brinell

140 HB
158 HB

Hardness, Rockwell B

76 HRB
82 HRB

Hardness, Vickers

148 HV
168 HV

Same in both: Elastic (Young's) Modulus 128 GPa18.6 Msi · Shear Modulus 48 GPa7 Msi · Bulk Modulus 125 GPa18.1 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 8.72 g/cm³0.32 lb/in³ · Melting Point (Solidus) 966°C1,771 °F · Liquidus Temperature 1,010°C1,850 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 40 W/m·K23.1 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.7 µm/m·K9.3 µin/in·°F · Latent Heat of Fusion 175 J/g75.2 BTU/lb · Max Service Temperature (continuous) 150°C302 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 9 % IACS · Electrical Resistivity 1.92×10⁻⁷ Ω·m7.56 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.24 V · Corrosion Resistance 62 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

62 / 100
63 / 100

Machinability Rating (AISI 1212 = 100 %)

60%
62%

Formability (cold)

45 / 100
35 / 100

Same in both: Weldability 20 / 100 · Brazeability / Solderability 55 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 72 MJ/kg30,954 BTU/lb · Embodied Carbon (primary production) 5 kg CO₂/kg · Embodied Water 260 L/kg31.2 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC78200

C78200-H02 vs C78200-H03 — frequently asked

Is C78200-H03 stronger than C78200-H02?

Yes. C78200-H03 has a typical yield strength of 462 MPa (67 ksi) against 407 MPa (59 ksi) for C78200-H02 — about 14% more. Tensile strength is 524 MPa (76 ksi) vs 483 MPa (70.1 ksi).

Which condition does FabDigit quote by default, H02 or H03?

H02 is the default C78200 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C78200-H02 over C78200-H03?

Pick C78200-H02 when the part is bent, formed or impact-loaded. Pick C78200-H03 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C78200-H02 and C78200-H03 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.