C76200-H01 and C76200-H06 are two conditions of the same copper alloy grade, C76200: H01 (quarter hard) versus H06 (extra hard). The chemistry is identical, so every difference below comes from the condition. C76200-H06 is the stronger of the two: yield strength 586 MPa (85 ksi) against 310 MPa (45 ksi) for C76200-H01, about 89% more; tensile strength follows at 655 MPa (95 ksi) vs 450 MPa (65.3 ksi). In exchange, C76200-H01 is the more ductile: elongation 25% versus 2% for C76200-H06, and C76200-H06 is harder (190 HB vs 130 HB). C76200-H01 runs hotter in service (200°C vs 150°C continuous).

C76200-H01Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C76200-H06Choose it when strength drives the design.

C76200-H01 vs C76200-H06: properties

C76200-H01C76200-H06

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

450 MPa65.3 ksi
655 MPa95 ksi

Yield Strength (0.2% offset)

310 MPa45 ksi
586 MPa85 ksi

Elongation at Break

25%
2%

Shear Strength

305 MPa44.2 ksi
365 MPa52.9 ksi

Fatigue Strength (Endurance Limit)

195 MPa28.3 ksi
240 MPa34.8 ksi

Hardness, Brinell

130 HB
190 HB

Hardness, Rockwell B

72 HRB
91 HRB

Hardness, Vickers

138 HV
200 HV

Same in both: Elastic (Young's) Modulus 124 GPa18 Msi · Shear Modulus 46 GPa6.7 Msi · Bulk Modulus 129 GPa18.7 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.7 g/cm³0.31 lb/in³ · Melting Point (Solidus) 1,010°C1,850 °F · Liquidus Temperature 1,050°C1,922 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

200°C392 °F
150°C302 °F

Same in both: Thermal Conductivity 29 W/m·K16.8 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.2 µm/m·K9 µin/in·°F · Latent Heat of Fusion 175 J/g75.2 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

5.7 % IACS
5.5 % IACS

Same in both: Electrical Resistivity 3.13×10⁻⁷ Ω·m12.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.19 V · Corrosion Resistance 62 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

30 / 100
35 / 100

Formability (cold)

75 / 100
30 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 20% · Weldability 50 / 100 · Brazeability / Solderability 85 / 100 · Polishability 90 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 72 MJ/kg30,954 BTU/lb · Embodied Carbon (primary production) 5 kg CO₂/kg · Embodied Water 320 L/kg38.3 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC76200

C76200-H01 vs C76200-H06 — frequently asked

Is C76200-H06 stronger than C76200-H01?

Yes. C76200-H06 has a typical yield strength of 586 MPa (85 ksi) against 310 MPa (45 ksi) for C76200-H01 — about 89% more. Tensile strength is 655 MPa (95 ksi) vs 450 MPa (65.3 ksi).

Which condition does FabDigit quote by default, H01 or H06?

H02 is the default C76200 condition in the FabDigit quote flow (neither H01 nor H06). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C76200-H01 or C76200-H06?

C76200-H06. Its machinability rates fair (35/100) against poor (30/100) for C76200-H01.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C76200-H01 and C76200-H06 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.