FabDigitFabDigit

Copper Alloy C75200-H04 vs C75200-H10

Copper Alloy · C75200 temper comparison

C75200-H04 and C75200-H10 are two conditions of the same copper alloy grade, C75200: H04 (full hard) versus H10 (extra spring hard). The chemistry is identical, so every difference below comes from the condition. C75200-H10 is the stronger of the two: yield strength 690 MPa (100 ksi) against 517 MPa (75 ksi) for C75200-H04, about 33% more; tensile strength follows at 758 MPa (110 ksi) vs 586 MPa (85 ksi). In exchange, C75200-H04 is the more ductile: elongation 3% versus 1% for C75200-H10, and C75200-H10 is harder (215 HB vs 177 HB). C75200-H04 runs hotter in service (180°C vs 150°C continuous).

C75200-H04Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C75200-H10Choose it when strength drives the design.

C75200-H04 vs C75200-H10: properties

C75200-H04C75200-H10

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

125 GPa18.1 Msi
128 GPa18.6 Msi

Tensile Strength (Ultimate)

586 MPa85 ksi
758 MPa110 ksi

Yield Strength (0.2% offset)

517 MPa75 ksi
690 MPa100 ksi

Elongation at Break

3%
1%

Shear Strength

372 MPa54 ksi
440 MPa63.8 ksi

Fatigue Strength (Endurance Limit)

200 MPa29 ksi
225 MPa32.6 ksi

Hardness, Brinell

177 HB
215 HB

Hardness, Rockwell B

89 HRB
96 HRB

Hardness, Vickers

188 HV
225 HV

Same in both: Shear Modulus 47 GPa6.8 Msi · Bulk Modulus 122 GPa17.7 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 8.73 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,021°C1,870 °F · Liquidus Temperature 1,110°C2,030 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

33 W/m·K19.1 BTU/hr·ft·°F
32 W/m·K18.5 BTU/hr·ft·°F

Max Service Temperature (continuous)

180°C356 °F
150°C302 °F

Same in both: Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.2 µm/m·K9 µin/in·°F · Latent Heat of Fusion 200 J/g86 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

6 % IACS
5.5 % IACS

Electrical Resistivity

2.87×10⁻⁷ Ω·m11.3 µΩ·in
3.13×10⁻⁷ Ω·m12.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

65 / 100
62 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.26 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

28 / 100
30 / 100

Machinability Rating (AISI 1212 = 100 %)

20%
25%

Weldability

40 / 100
35 / 100

Formability (cold)

32 / 100
12 / 100

Same in both: Castability 40 / 100 · Brazeability / Solderability 85 / 100 · Polishability 92 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 82 MJ/kg35,254 BTU/lb · Embodied Carbon (primary production) 5.6 kg CO₂/kg · Embodied Water 320 L/kg38.3 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC75200

C75200-H04 vs C75200-H10 — frequently asked

Is C75200-H10 stronger than C75200-H04?

Yes. C75200-H10 has a typical yield strength of 690 MPa (100 ksi) against 517 MPa (75 ksi) for C75200-H04 — about 33% more. Tensile strength is 758 MPa (110 ksi) vs 586 MPa (85 ksi).

Which condition does FabDigit quote by default, H04 or H10?

H02 is the default C75200 condition in the FabDigit quote flow (neither H04 nor H10). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, C75200-H04 or C75200-H10?

C75200-H04. Its weldability rates fair (40/100) against fair (35/100) for C75200-H10.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C75200-H04 and C75200-H10 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.