FabDigitFabDigit

Copper Alloy C73500-H02 vs C73500-H06

Copper Alloy · C73500 temper comparison

C73500-H02 and C73500-H06 are two conditions of the same copper alloy grade, C73500: H02 (half hard) versus H06 (extra hard). The chemistry is identical, so every difference below comes from the condition. C73500-H06 is the stronger of the two: yield strength 570 MPa (82.7 ksi) against 415 MPa (60.2 ksi) for C73500-H02, about 37% more; tensile strength follows at 655 MPa (95 ksi) vs 480 MPa (69.6 ksi). In exchange, C73500-H02 is the more ductile: elongation 10% versus 3% for C73500-H06, and C73500-H06 is harder (180 HB vs 130 HB). C73500-H02 runs hotter in service (175°C vs 150°C continuous).

C73500-H02Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C73500-H06Choose it when strength drives the design.

C73500-H02 vs C73500-H06: properties

C73500-H02C73500-H06

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

480 MPa69.6 ksi
655 MPa95 ksi

Yield Strength (0.2% offset)

415 MPa60.2 ksi
570 MPa82.7 ksi

Elongation at Break

10%
3%

Shear Strength

330 MPa47.9 ksi
400 MPa58 ksi

Fatigue Strength (Endurance Limit)

210 MPa30.5 ksi
250 MPa36.3 ksi

Hardness, Brinell

130 HB
180 HB

Hardness, Rockwell B

72 HRB
87 HRB

Hardness, Vickers

140 HV
195 HV

Same in both: Elastic (Young's) Modulus 127 GPa18.4 Msi · Shear Modulus 47 GPa6.8 Msi · Bulk Modulus 128 GPa18.6 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.86 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,080°C1,976 °F · Liquidus Temperature 1,110°C2,030 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

175°C347 °F
150°C302 °F

Same in both: Thermal Conductivity 33 W/m·K19.1 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.2 µm/m·K9 µin/in·°F · Latent Heat of Fusion 210 J/g90.3 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

6.2 % IACS
6 % IACS

Same in both: Electrical Resistivity 2.78×10⁻⁷ Ω·m10.9 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V · Corrosion Resistance 62 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

30 / 100
32 / 100

Formability (cold)

55 / 100
25 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 20% · Weldability 55 / 100 · Castability 40 / 100 · Brazeability / Solderability 85 / 100 · Polishability 90 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 78 MJ/kg33,534 BTU/lb · Embodied Carbon (primary production) 5.6 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC73500

C73500-H02 vs C73500-H06 — frequently asked

Is C73500-H06 stronger than C73500-H02?

Yes. C73500-H06 has a typical yield strength of 570 MPa (82.7 ksi) against 415 MPa (60.2 ksi) for C73500-H02 — about 37% more. Tensile strength is 655 MPa (95 ksi) vs 480 MPa (69.6 ksi).

Which condition does FabDigit quote by default, H02 or H06?

H02 is the default C73500 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C73500-H02 over C73500-H06?

Pick C73500-H02 when the part is bent, formed or impact-loaded, or when the part sees heat. Pick C73500-H06 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C73500-H02 and C73500-H06 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.