C73200-H02 and C73200-H08 are two conditions of the same copper alloy grade, C73200: H02 (half hard) versus H08 (spring hard). The chemistry is identical, so every difference below comes from the condition. C73200-H08 is the stronger of the two: yield strength 545 MPa (79 ksi) against 380 MPa (55.1 ksi) for C73200-H02, about 43% more; tensile strength follows at 635 MPa (92.1 ksi) vs 470 MPa (68.2 ksi). In exchange, C73200-H02 is the more ductile: elongation 12% versus 2% for C73200-H08, and C73200-H08 is harder (185 HB vs 130 HB). C73200-H02 runs hotter in service (200°C vs 150°C continuous). On the shop floor, C73200-H08 machines more easily (fair vs poor) and C73200-H02 welds better (good vs fair).

C73200-H02Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C73200-H08Choose it when strength drives the design, or when the part is machined in volume.

C73200-H02 vs C73200-H08: properties

C73200-H02C73200-H08

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

125 GPa18.1 Msi
128 GPa18.6 Msi

Tensile Strength (Ultimate)

470 MPa68.2 ksi
635 MPa92.1 ksi

Yield Strength (0.2% offset)

380 MPa55.1 ksi
545 MPa79 ksi

Elongation at Break

12%
2%

Reduction in Area

30%
8%

Compressive Strength

390 MPa56.6 ksi
560 MPa81.2 ksi

Shear Strength

320 MPa46.4 ksi
395 MPa57.3 ksi

Fatigue Strength (Endurance Limit)

175 MPa25.4 ksi
215 MPa31.2 ksi

Charpy V-Notch Impact (RT)

25 J18.4 ft·lbf
10 J7.4 ft·lbf

Hardness, Brinell

130 HB
185 HB

Hardness, Rockwell B

70 HRB
88 HRB

Hardness, Vickers

140 HV
192 HV

Same in both: Shear Modulus 47 GPa6.8 Msi · Bulk Modulus 125 GPa18.1 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 8.73 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,060°C1,940 °F · Liquidus Temperature 1,100°C2,012 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

45 W/m·K26 BTU/hr·ft·°F
44 W/m·K25.4 BTU/hr·ft·°F

Max Service Temperature (continuous)

200°C392 °F
150°C302 °F

Same in both: Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.2 µm/m·K9 µin/in·°F · Latent Heat of Fusion 200 J/g86 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

11 % IACS
10.5 % IACS

Electrical Resistivity

1.57×10⁻⁷ Ω·m6.18 µΩ·in
1.64×10⁻⁷ Ω·m6.46 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

65 / 100
60 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

25 / 100
35 / 100

Machinability Rating (AISI 1212 = 100 %)

20%
28%

Weldability

55 / 100
45 / 100

Formability (cold)

70 / 100
20 / 100

Same in both: Brazeability / Solderability 85 / 100 · Polishability 90 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 62 MJ/kg26,655 BTU/lb · Embodied Carbon (primary production) 4.3 kg CO₂/kg · Embodied Water 260 L/kg31.2 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC73200

C73200-H02 vs C73200-H08 — frequently asked

Is C73200-H08 stronger than C73200-H02?

Yes. C73200-H08 has a typical yield strength of 545 MPa (79 ksi) against 380 MPa (55.1 ksi) for C73200-H02 — about 43% more. Tensile strength is 635 MPa (92.1 ksi) vs 470 MPa (68.2 ksi).

Which condition does FabDigit quote by default, H02 or H08?

H02 is the default C73200 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C73200-H02 or C73200-H08?

C73200-H08. Its machinability rates fair (35/100) against poor (25/100) for C73200-H02; for welding the order is C73200-H02 first (good, 55/100) then C73200-H08 (fair, 45/100).