FabDigitFabDigit

Copper Alloy C72800-H08 vs C72800-TF00

Copper Alloy · C72800 temper comparison

C72800-H08 and C72800-TF00 are two conditions of the same copper alloy grade, C72800: H08 (spring hard) versus TF00 (solution heat treated and precipitation hardened). The chemistry is identical, so every difference below comes from the condition. C72800-H08 is the stronger of the two: yield strength 880 MPa (128 ksi) against 800 MPa (116 ksi) for C72800-TF00, about 10% more. In exchange, C72800-TF00 is the more ductile: elongation 12% versus 3% for C72800-H08, and C72800-TF00 is harder (30 HRC vs 26 HRC). C72800-TF00 runs hotter in service (200°C vs 150°C continuous).

C72800-H08Choose it when strength drives the design.

C72800-TF00Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C72800-H08 vs C72800-TF00: properties

C72800-H08C72800-TF00

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Yield Strength (0.2% offset)

880 MPa128 ksi
800 MPa116 ksi

Elongation at Break

3%
12%

Shear Strength

555 MPa80.5 ksi
560 MPa81.2 ksi

Fatigue Strength (Endurance Limit)

320 MPa46.4 ksi
340 MPa49.3 ksi

Hardness, Rockwell C

26 HRC
30 HRC

Hardness, Vickers

275 HV
300 HV

Same in both: Elastic (Young's) Modulus 135 GPa19.6 Msi · Shear Modulus 51 GPa7.4 Msi · Bulk Modulus 115 GPa16.7 Msi · Poisson's Ratio 0.3 · Tensile Strength (Ultimate) 930 MPa135 ksi · Reduction in Area 25% · Charpy V-Notch Impact (RT) 20 J14.8 ft·lbf · Hardness, Brinell 285 HB

Physical

Density and transition temperatures.

Same in both: Density 8.86 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,030°C1,886 °F · Liquidus Temperature 1,090°C1,994 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

150°C302 °F
200°C392 °F

Same in both: Thermal Conductivity 35 W/m·K20.2 BTU/hr·ft·°F · Specific Heat Capacity 380 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.5 µm/m·K9.2 µin/in·°F · Latent Heat of Fusion 190 J/g81.7 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

7.5 % IACS
8 % IACS

Same in both: Electrical Resistivity 2.16×10⁻⁷ Ω·m8.5 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V · Corrosion Resistance 74 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Formability (cold)

20 / 100
35 / 100

Same in both: Machinability 35 / 100 · Machinability Rating (AISI 1212 = 100 %) 20% · Weldability 40 / 100 · Castability 45 / 100 · Brazeability / Solderability 65 / 100 · Polishability 85 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 72 MJ/kg30,954 BTU/lb · Embodied Carbon (primary production) 5.2 kg CO₂/kg · Embodied Water 260 L/kg31.2 gal/lb · Typical Recycled Content 20%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC72800

C72800-H08 vs C72800-TF00 — frequently asked

Is C72800-H08 stronger than C72800-TF00?

Yes. C72800-H08 has a typical yield strength of 880 MPa (128 ksi) against 800 MPa (116 ksi) for C72800-TF00 — about 10% more. Tensile strength is 930 MPa (135 ksi) vs 930 MPa (135 ksi).

Which condition does FabDigit quote by default, H08 or TF00?

TF00 is the default C72800 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C72800-H08 over C72800-TF00?

Pick C72800-H08 when strength drives the design. Pick C72800-TF00 when the part is bent, formed or impact-loaded, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C72800-H08 and C72800-TF00 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.