FabDigitFabDigit

Copper Alloy C69700-H02 vs C69700-M20

Copper Alloy · C69700 temper comparison

C69700-H02 and C69700-M20 are two conditions of the same copper alloy grade, C69700: H02 (half hard) versus M20 (as hot rolled). The chemistry is identical, so every difference below comes from the condition. C69700-H02 is the stronger of the two: yield strength 450 MPa (65.3 ksi) against 240 MPa (34.8 ksi) for C69700-M20, about 88% more; tensile strength follows at 620 MPa (89.9 ksi) vs 485 MPa (70.3 ksi). In exchange, C69700-M20 is the more ductile: elongation 28% versus 12% for C69700-H02, and C69700-H02 is harder (170 HB vs 120 HB).

C69700-H02Choose it when strength drives the design.

C69700-M20Choose it when the part is bent, formed or impact-loaded.

C69700-H02 vs C69700-M20: properties

C69700-H02C69700-M20

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

620 MPa89.9 ksi
485 MPa70.3 ksi

Yield Strength (0.2% offset)

450 MPa65.3 ksi
240 MPa34.8 ksi

Elongation at Break

12%
28%

Shear Strength

360 MPa52.2 ksi
300 MPa43.5 ksi

Fatigue Strength (Endurance Limit)

185 MPa26.8 ksi
160 MPa23.2 ksi

Hardness, Brinell

170 HB
120 HB

Hardness, Rockwell B

86 HRB
68 HRB

Same in both: Elastic (Young's) Modulus 105 GPa15.2 Msi · Shear Modulus 39 GPa5.7 Msi · Bulk Modulus 110 GPa16 Msi · Poisson's Ratio 0.34 · Charpy V-Notch Impact (RT) 30 J22.1 ft·lbf

Physical

Density and transition temperatures.

Same in both: Density 8.3 g/cm³0.3 lb/in³ · Melting Point (Solidus) 820°C1,508 °F · Liquidus Temperature 900°C1,652 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 33 W/m·K19.1 BTU/hr·ft·°F · Specific Heat Capacity 380 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 20.5 µm/m·K11.4 µin/in·°F · Latent Heat of Fusion 175 J/g75.2 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 6.5 % IACS · Electrical Resistivity 2.65×10⁻⁷ Ω·m10.4 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V · Corrosion Resistance 62 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

78 / 100
72 / 100

Machinability Rating (AISI 1212 = 100 %)

75%
70%

Formability (cold)

25 / 100
45 / 100

Same in both: Weldability 25 / 100 · Brazeability / Solderability 70 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 45 MJ/kg19,347 BTU/lb · Embodied Carbon (primary production) 2.9 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC69700

C69700-H02 vs C69700-M20 — frequently asked

Is C69700-H02 stronger than C69700-M20?

Yes. C69700-H02 has a typical yield strength of 450 MPa (65.3 ksi) against 240 MPa (34.8 ksi) for C69700-M20 — about 88% more. Tensile strength is 620 MPa (89.9 ksi) vs 485 MPa (70.3 ksi).

Which condition does FabDigit quote by default, H02 or M20?

M20 is the default C69700 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C69700-H02 or C69700-M20?

C69700-H02, by a small margin. Both rate very good for machinability — 78/100 against 72/100 for C69700-M20.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C69700-H02 and C69700-M20 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.