C68300-H02 and C68300-H80 are two conditions of the same copper alloy grade, C68300: H02 (half hard) versus H80 (hard drawn). The chemistry is identical, so every difference below comes from the condition. C68300-H80 is the stronger of the two: yield strength 380 MPa (55.1 ksi) against 320 MPa (46.4 ksi) for C68300-H02, about 19% more; tensile strength follows at 460 MPa (66.7 ksi) vs 425 MPa (61.6 ksi). In exchange, C68300-H02 is the more ductile: elongation 23% versus 10% for C68300-H80, and C68300-H80 is harder (130 HB vs 110 HB).

C68300-H02Choose it when the part is bent, formed or impact-loaded.

C68300-H80Choose it when strength drives the design.

C68300-H02 vs C68300-H80: properties

C68300-H02C68300-H80

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

425 MPa61.6 ksi
460 MPa66.7 ksi

Yield Strength (0.2% offset)

320 MPa46.4 ksi
380 MPa55.1 ksi

Elongation at Break

23%
10%

Shear Strength

265 MPa38.4 ksi
285 MPa41.3 ksi

Fatigue Strength (Endurance Limit)

140 MPa20.3 ksi
150 MPa21.8 ksi

Charpy V-Notch Impact (RT)

45 J33.2 ft·lbf
35 J25.8 ft·lbf

Hardness, Brinell

110 HB
130 HB

Hardness, Rockwell B

70 HRB
76 HRB

Hardness, Vickers

116 HV
137 HV

Same in both: Elastic (Young's) Modulus 110 GPa16 Msi · Shear Modulus 41 GPa5.9 Msi · Bulk Modulus 115 GPa16.7 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.53 g/cm³0.31 lb/in³ · Melting Point (Solidus) 927°C1,701 °F · Liquidus Temperature 954°C1,749 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

131 W/m·K75.7 BTU/hr·ft·°F
130 W/m·K75.1 BTU/hr·ft·°F

Max Service Temperature (continuous)

160°C320 °F
150°C302 °F

Same in both: Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 20 µm/m·K11.1 µin/in·°F · Latent Heat of Fusion 170 J/g73.1 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

29.5 % IACS
29 % IACS

Electrical Resistivity

5.85×10⁻⁸ Ω·m2.3 µΩ·in
5.95×10⁻⁸ Ω·m2.34 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

65 / 100
64 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.26 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

36 / 100
38 / 100

Machinability Rating (AISI 1212 = 100 %)

36%
38%

Weldability

53 / 100
52 / 100

Formability (cold)

55 / 100
35 / 100

Same in both: Castability 45 / 100 · Brazeability / Solderability 92 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC68300

C68300-H02 vs C68300-H80 — frequently asked

Is C68300-H80 stronger than C68300-H02?

Yes. C68300-H80 has a typical yield strength of 380 MPa (55.1 ksi) against 320 MPa (46.4 ksi) for C68300-H02 — about 19% more. Tensile strength is 460 MPa (66.7 ksi) vs 425 MPa (61.6 ksi).

Which condition does FabDigit quote by default, H02 or H80?

O61 is the default C68300 condition in the FabDigit quote flow (neither H02 nor H80). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C68300-H02 over C68300-H80?

Pick C68300-H02 when the part is bent, formed or impact-loaded. Pick C68300-H80 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C68300-H02 and C68300-H80 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.