FabDigitFabDigit

Copper Alloy C66300-H04 vs C66300-O60

Copper Alloy · C66300 temper comparison

C66300-H04 and C66300-O60 are two conditions of the same copper alloy grade, C66300: H04 (full hard) versus O60 (soft annealed). The chemistry is identical, so every difference below comes from the condition. C66300-H04 is the stronger of the two: yield strength 490 MPa (71.1 ksi) against 145 MPa (21 ksi) for C66300-O60, about 3.4 times as much; tensile strength follows at 570 MPa (82.7 ksi) vs 375 MPa (54.4 ksi). In exchange, C66300-O60 is the more ductile: elongation 45% versus 8% for C66300-H04, and C66300-H04 is harder (170 HV vs 90 HV). C66300-O60 runs hotter in service (200°C vs 120°C continuous).

C66300-H04Choose it when strength drives the design.

C66300-O60Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C66300-H04 vs C66300-O60: properties

C66300-H04C66300-O60

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

570 MPa82.7 ksi
375 MPa54.4 ksi

Yield Strength (0.2% offset)

490 MPa71.1 ksi
145 MPa21 ksi

Elongation at Break

8%
45%

Shear Strength

335 MPa48.6 ksi
240 MPa34.8 ksi

Fatigue Strength (Endurance Limit)

165 MPa23.9 ksi
125 MPa18.1 ksi

Hardness, Rockwell B

78 HRB
48 HRB

Hardness, Vickers

170 HV
90 HV

Same in both: Elastic (Young's) Modulus 110 GPa16 Msi · Shear Modulus 41 GPa5.9 Msi · Bulk Modulus 115 GPa16.7 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.55 g/cm³0.31 lb/in³ · Melting Point (Solidus) 900°C1,652 °F · Liquidus Temperature 935°C1,715 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

105 W/m·K60.7 BTU/hr·ft·°F
110 W/m·K63.6 BTU/hr·ft·°F

Max Service Temperature (continuous)

120°C248 °F
200°C392 °F

Same in both: Specific Heat Capacity 375 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 19.9 µm/m·K11.1 µin/in·°F · Latent Heat of Fusion 170 J/g73.1 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

25 % IACS
27 % IACS

Electrical Resistivity

6.9×10⁻⁸ Ω·m2.72 µΩ·in
6.4×10⁻⁸ Ω·m2.52 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

58 / 100
62 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

33 / 100
25 / 100

Machinability Rating (AISI 1212 = 100 %)

30%
25%

Weldability

30 / 100
32 / 100

Formability (cold)

32 / 100
90 / 100

Same in both: Brazeability / Solderability 80 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 58 MJ/kg24,936 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 260 L/kg31.2 gal/lb · Typical Recycled Content 50%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC66300

C66300-H04 vs C66300-O60 — frequently asked

Is C66300-H04 stronger than C66300-O60?

Yes. C66300-H04 has a typical yield strength of 490 MPa (71.1 ksi) against 145 MPa (21 ksi) for C66300-O60 — about 3.4 times as much. Tensile strength is 570 MPa (82.7 ksi) vs 375 MPa (54.4 ksi).

Which condition does FabDigit quote by default, H04 or O60?

H08 is the default C66300 condition in the FabDigit quote flow (neither H04 nor O60). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C66300-H04 or C66300-O60?

C66300-H04, by a small margin. Both rate poor for machinability — 33/100 against 25/100 for C66300-O60.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C66300-H04 and C66300-O60 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.