FabDigitFabDigit

Copper Alloy C66300-H02 vs C66300-H08

Copper Alloy · C66300 temper comparison

C66300-H02 and C66300-H08 are two conditions of the same copper alloy grade, C66300: H02 (half hard) versus H08 (spring hard). The chemistry is identical, so every difference below comes from the condition. C66300-H08 is the stronger of the two: yield strength 600 MPa (87 ksi) against 400 MPa (58 ksi) for C66300-H02, about 50% more; tensile strength follows at 660 MPa (95.7 ksi) vs 500 MPa (72.5 ksi). In exchange, C66300-H02 is the more ductile: elongation 15% versus 3.5% for C66300-H08, and C66300-H08 is harder (195 HV vs 145 HV). C66300-H02 runs hotter in service (150°C vs 120°C continuous).

C66300-H02Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C66300-H08Choose it when strength drives the design.

C66300-H02 vs C66300-H08: properties

C66300-H02C66300-H08

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

500 MPa72.5 ksi
660 MPa95.7 ksi

Yield Strength (0.2% offset)

400 MPa58 ksi
600 MPa87 ksi

Elongation at Break

15%
3.5%

Shear Strength

300 MPa43.5 ksi
380 MPa55.1 ksi

Fatigue Strength (Endurance Limit)

155 MPa22.5 ksi
180 MPa26.1 ksi

Hardness, Rockwell B

68 HRB
85 HRB

Hardness, Vickers

145 HV
195 HV

Same in both: Elastic (Young's) Modulus 110 GPa16 Msi · Shear Modulus 41 GPa5.9 Msi · Bulk Modulus 115 GPa16.7 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.55 g/cm³0.31 lb/in³ · Melting Point (Solidus) 900°C1,652 °F · Liquidus Temperature 935°C1,715 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

150°C302 °F
120°C248 °F

Same in both: Thermal Conductivity 105 W/m·K60.7 BTU/hr·ft·°F · Specific Heat Capacity 375 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 19.9 µm/m·K11.1 µin/in·°F · Latent Heat of Fusion 170 J/g73.1 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 25 % IACS · Electrical Resistivity 6.9×10⁻⁸ Ω·m2.72 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V · Corrosion Resistance 58 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

30 / 100
35 / 100

Formability (cold)

45 / 100
20 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 30% · Weldability 30 / 100 · Brazeability / Solderability 80 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 58 MJ/kg24,936 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 260 L/kg31.2 gal/lb · Typical Recycled Content 50%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC66300

C66300-H02 vs C66300-H08 — frequently asked

Is C66300-H08 stronger than C66300-H02?

Yes. C66300-H08 has a typical yield strength of 600 MPa (87 ksi) against 400 MPa (58 ksi) for C66300-H02 — about 50% more. Tensile strength is 660 MPa (95.7 ksi) vs 500 MPa (72.5 ksi).

Which condition does FabDigit quote by default, H02 or H08?

H08 is the default C66300 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C66300-H02 or C66300-H08?

C66300-H08. Its machinability rates fair (35/100) against poor (30/100) for C66300-H02.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C66300-H02 and C66300-H08 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.