FabDigitFabDigit

Copper Alloy C64800-TB00 vs C64800-TH02

Copper Alloy · C64800 temper comparison

C64800-TB00 and C64800-TH02 are two conditions of the same copper alloy grade, C64800: TB00 (solution heat treated) versus TH02 (TD02 and precipitation hardened). The chemistry is identical, so every difference below comes from the condition. C64800-TH02 is the stronger of the two: yield strength 650 MPa (94.3 ksi) against 165 MPa (23.9 ksi) for C64800-TB00, about 3.9 times as much; tensile strength follows at 720 MPa (104 ksi) vs 410 MPa (59.5 ksi). In exchange, C64800-TB00 is the more ductile: elongation 35% versus 8% for C64800-TH02, and C64800-TH02 is harder (225 HV vs 92 HV). C64800-TH02 runs hotter in service (200°C vs 150°C continuous) and C64800-TH02 conducts heat better (172 W/m·K vs 95 W/m·K). On the shop floor, C64800-TB00 welds better (very good vs fair).

C64800-TB00Choose it when the part is bent, formed or impact-loaded, or when it will be welded.

C64800-TH02Choose it when strength drives the design, or when the part sees heat.

C64800-TB00 vs C64800-TH02: properties

C64800-TB00C64800-TH02

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

410 MPa59.5 ksi
720 MPa104 ksi

Yield Strength (0.2% offset)

165 MPa23.9 ksi
650 MPa94.3 ksi

Elongation at Break

35%
8%

Shear Strength

270 MPa39.2 ksi
440 MPa63.8 ksi

Fatigue Strength (Endurance Limit)

160 MPa23.2 ksi
270 MPa39.2 ksi

Hardness, Rockwell B

45 HRB
95 HRB

Hardness, Vickers

92 HV
225 HV

Same in both: Elastic (Young's) Modulus 130 GPa18.9 Msi · Shear Modulus 48 GPa7 Msi · Bulk Modulus 120 GPa17.4 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.8 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,030°C1,886 °F · Liquidus Temperature 1,075°C1,967 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

95 W/m·K54.9 BTU/hr·ft·°F
172 W/m·K99.4 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
200°C392 °F

Same in both: Specific Heat Capacity 380 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.5 µm/m·K9.7 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

22 % IACS
44 % IACS

Electrical Resistivity

7.84×10⁻⁸ Ω·m3.09 µΩ·in
3.92×10⁻⁸ Ω·m1.54 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V · Corrosion Resistance 70 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

30 / 100
35 / 100

Machinability Rating (AISI 1212 = 100 %)

25%
30%

Weldability

70 / 100
50 / 100

Formability (cold)

80 / 100
35 / 100

Same in both: Brazeability / Solderability 75 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 58 MJ/kg24,936 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC64800

C64800-TB00 vs C64800-TH02 — frequently asked

Is C64800-TH02 stronger than C64800-TB00?

Yes. C64800-TH02 has a typical yield strength of 650 MPa (94.3 ksi) against 165 MPa (23.9 ksi) for C64800-TB00 — about 3.9 times as much. Tensile strength is 720 MPa (104 ksi) vs 410 MPa (59.5 ksi).

Which condition does FabDigit quote by default, TB00 or TH02?

TF00 is the default C64800 condition in the FabDigit quote flow (neither TB00 nor TH02). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C64800-TB00 or C64800-TH02?

C64800-TH02. Its machinability rates fair (35/100) against poor (30/100) for C64800-TB00; for welding the order is C64800-TB00 first (very good, 70/100) then C64800-TH02 (fair, 50/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in C64800-TB00 and C64800-TH02 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.