FabDigitFabDigit

Copper Alloy C62580-M11 vs C62580-O60

Copper Alloy · C62580 temper comparison

C62580-M11 and C62580-O60 are two conditions of the same copper alloy grade, C62580: M11 (as forged and quenched) versus O60 (soft annealed). The chemistry is identical, so every difference below comes from the condition. C62580-M11 is the stronger of the two: yield strength 414 MPa (60 ksi) against 350 MPa (50.8 ksi) for C62580-O60, about 18% more; tensile strength follows at 758 MPa (110 ksi) vs 700 MPa (102 ksi). In exchange, C62580-O60 is the more ductile: elongation 8% versus 6% for C62580-M11, and C62580-M11 is harder (235 HB vs 217 HB).

C62580-M11Choose it when strength drives the design.

C62580-O60Choose it when the part is bent, formed or impact-loaded.

C62580-M11 vs C62580-O60: properties

C62580-M11C62580-O60

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

758 MPa110 ksi
700 MPa102 ksi

Yield Strength (0.2% offset)

414 MPa60 ksi
350 MPa50.8 ksi

Elongation at Break

6%
8%

Reduction in Area

9%
8%

Shear Strength

462 MPa67 ksi
465 MPa67.4 ksi

Fatigue Strength (Endurance Limit)

245 MPa35.5 ksi
225 MPa32.6 ksi

Charpy V-Notch Impact (RT)

11 J8.1 ft·lbf
14 J10.3 ft·lbf

Hardness, Brinell

235 HB
217 HB

Hardness, Vickers

247 HV
228 HV

Same in both: Elastic (Young's) Modulus 110 GPa16 Msi · Shear Modulus 42 GPa6.1 Msi · Bulk Modulus 105 GPa15.2 Msi · Poisson's Ratio 0.32 · Hardness, Rockwell C 22 HRC

Physical

Density and transition temperatures.

Same in both: Density 7.25 g/cm³0.26 lb/in³ · Melting Point (Solidus) 1,027°C1,881 °F · Liquidus Temperature 1,046°C1,915 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 42 W/m·K24.3 BTU/hr·ft·°F · Specific Heat Capacity 375 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.2 µm/m·K9 µin/in·°F · Latent Heat of Fusion 220 J/g94.6 BTU/lb · Max Service Temperature (continuous) 300°C572 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 7.5 % IACS · Electrical Resistivity 2.3×10⁻⁷ Ω·m9.06 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.27 V · Corrosion Resistance 70 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

27 / 100
30 / 100

Machinability Rating (AISI 1212 = 100 %)

22%
25%

Weldability

32 / 100
30 / 100

Formability (cold)

12 / 100
15 / 100

Same in both: Castability 55 / 100 · Brazeability / Solderability 30 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 58 MJ/kg24,936 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 320 L/kg38.3 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC62580

C62580-M11 vs C62580-O60 — frequently asked

Is C62580-M11 stronger than C62580-O60?

Yes. C62580-M11 has a typical yield strength of 414 MPa (60 ksi) against 350 MPa (50.8 ksi) for C62580-O60 — about 18% more. Tensile strength is 758 MPa (110 ksi) vs 700 MPa (102 ksi).

Which condition does FabDigit quote by default, M11 or O60?

M30 is the default C62580 condition in the FabDigit quote flow (neither M11 nor O60). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C62580-M11 over C62580-O60?

Pick C62580-M11 when strength drives the design. Pick C62580-O60 when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C62580-M11 and C62580-O60 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.