FabDigitFabDigit

Copper Alloy C62500-M10 vs C62500-O60

Copper Alloy · C62500 temper comparison

C62500-M10 and C62500-O60 are two conditions of the same copper alloy grade, C62500: M10 (as hot forged and air cooled) versus O60 (soft annealed). The chemistry is identical, so every difference below comes from the condition. C62500-M10 is the stronger of the two: yield strength 400 MPa (58 ksi) against 340 MPa (49.3 ksi) for C62500-O60, about 18% more; tensile strength follows at 740 MPa (107 ksi) vs 620 MPa (89.9 ksi). C62500-M10 is harder — 230 HB against 195 HB for C62500-O60 — which matters for wear surfaces and threads.

C62500-M10Choose it when strength drives the design, or when surface hardness matters.

C62500-M10 vs C62500-O60: properties

C62500-M10C62500-O60

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

740 MPa107 ksi
620 MPa89.9 ksi

Yield Strength (0.2% offset)

400 MPa58 ksi
340 MPa49.3 ksi

Reduction in Area

5%
7%

Compressive Strength

870 MPa126 ksi
740 MPa107 ksi

Shear Strength

470 MPa68.2 ksi
400 MPa58 ksi

Fatigue Strength (Endurance Limit)

240 MPa34.8 ksi
205 MPa29.7 ksi

Charpy V-Notch Impact (RT)

6 J4.4 ft·lbf
9 J6.6 ft·lbf

Hardness, Brinell

230 HB
195 HB

Hardness, Rockwell B

98 HRB
92 HRB

Hardness, Rockwell C

21 HRC
13 HRC

Hardness, Vickers

240 HV
205 HV

Same in both: Elastic (Young's) Modulus 114 GPa16.5 Msi · Shear Modulus 43 GPa6.2 Msi · Bulk Modulus 105 GPa15.2 Msi · Poisson's Ratio 0.32 · Elongation at Break 3%

Physical

Density and transition temperatures.

Same in both: Density 7.16 g/cm³0.26 lb/in³ · Melting Point (Solidus) 1,035°C1,895 °F · Liquidus Temperature 1,050°C1,922 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

41.9 W/m·K24.2 BTU/hr·ft·°F
43 W/m·K24.8 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 375 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.2 µm/m·K9 µin/in·°F · Latent Heat of Fusion 210 J/g90.3 BTU/lb · Max Service Temperature (continuous) 300°C572 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

8 % IACS
8.5 % IACS

Electrical Resistivity

2.16×10⁻⁷ Ω·m8.5 µΩ·in
2.03×10⁻⁷ Ω·m7.99 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

72 / 100
73 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.27 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

22 / 100
26 / 100

Machinability Rating (AISI 1212 = 100 %)

20%
25%

Weldability

25 / 100
30 / 100

Formability (cold)

12 / 100
18 / 100

Same in both: Castability 60 / 100 · Brazeability / Solderability 25 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 62 MJ/kg26,655 BTU/lb · Embodied Carbon (primary production) 3.9 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC62500

C62500-M10 vs C62500-O60 — frequently asked

Is C62500-M10 stronger than C62500-O60?

Yes. C62500-M10 has a typical yield strength of 400 MPa (58 ksi) against 340 MPa (49.3 ksi) for C62500-O60 — about 18% more. Tensile strength is 740 MPa (107 ksi) vs 620 MPa (89.9 ksi).

Which condition does FabDigit quote by default, M10 or O60?

M30 is the default C62500 condition in the FabDigit quote flow (neither M10 nor O60). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, C62500-M10 or C62500-O60?

C62500-O60. Its weldability rates poor (30/100) against poor (25/100) for C62500-M10.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C62500-M10 and C62500-O60 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.