FabDigitFabDigit

Copper Alloy C61800-H04 vs C61800-HR50

Copper Alloy · C61800 temper comparison

C61800-H04 and C61800-HR50 are two conditions of the same copper alloy grade, C61800: H04 (full hard) versus HR50 (hot rolled / hot worked plate and flats). The chemistry is identical, so every difference below comes from the condition. C61800-H04 is the stronger of the two: yield strength 415 MPa (60.2 ksi) against 300 MPa (43.5 ksi) for C61800-HR50, about 38% more; tensile strength follows at 655 MPa (95 ksi) vs 600 MPa (87 ksi). In exchange, C61800-HR50 is the more ductile: elongation 26% versus 18% for C61800-H04, and C61800-H04 is harder (195 HB vs 175 HB). C61800-HR50 runs hotter in service (300°C vs 250°C continuous). On the shop floor, C61800-HR50 welds better (very good vs good).

C61800-H04Choose it when strength drives the design.

C61800-HR50Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C61800-H04 vs C61800-HR50: properties

C61800-H04C61800-HR50

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

655 MPa95 ksi
600 MPa87 ksi

Yield Strength (0.2% offset)

415 MPa60.2 ksi
300 MPa43.5 ksi

Elongation at Break

18%
26%

Reduction in Area

25%
32%

Compressive Strength

700 MPa102 ksi
640 MPa92.8 ksi

Shear Strength

380 MPa55.1 ksi
360 MPa52.2 ksi

Fatigue Strength (Endurance Limit)

240 MPa34.8 ksi
230 MPa33.4 ksi

Fracture Toughness (K_IC)

45 MPa·√m41 ksi·√in
52 MPa·√m47.3 ksi·√in

Charpy V-Notch Impact (RT)

18 J13.3 ft·lbf
28 J20.7 ft·lbf

Hardness, Brinell

195 HB
175 HB

Hardness, Rockwell B

96 HRB
93 HRB

Hardness, Vickers

205 HV
185 HV

Same in both: Elastic (Young's) Modulus 117 GPa17 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 110 GPa16 Msi · Poisson's Ratio 0.32

Physical

Density and transition temperatures.

Same in both: Density 7.58 g/cm³0.27 lb/in³ · Melting Point (Solidus) 1,043°C1,909 °F · Liquidus Temperature 1,046°C1,915 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

55 W/m·K31.8 BTU/hr·ft·°F
56 W/m·K32.4 BTU/hr·ft·°F

Max Service Temperature (continuous)

250°C482 °F
300°C572 °F

Same in both: Specific Heat Capacity 419 J/kg·K0.1 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.2 µm/m·K9 µin/in·°F · Latent Heat of Fusion 210 J/g90.3 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

12.5 % IACS
13 % IACS

Electrical Resistivity

1.38×10⁻⁷ Ω·m5.43 µΩ·in
1.33×10⁻⁷ Ω·m5.24 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

75 / 100
78 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.31 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

35 / 100
30 / 100

Machinability Rating (AISI 1212 = 100 %)

45%
40%

Weldability

60 / 100
70 / 100

Formability (cold)

30 / 100
40 / 100

Same in both: Castability 55 / 100 · Brazeability / Solderability 30 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 3.7 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC61800

C61800-H04 vs C61800-HR50 — frequently asked

Is C61800-H04 stronger than C61800-HR50?

Yes. C61800-H04 has a typical yield strength of 415 MPa (60.2 ksi) against 300 MPa (43.5 ksi) for C61800-HR50 — about 38% more. Tensile strength is 655 MPa (95 ksi) vs 600 MPa (87 ksi).

Which condition does FabDigit quote by default, H04 or HR50?

M30 is the default C61800 condition in the FabDigit quote flow (neither H04 nor HR50). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C61800-H04 or C61800-HR50?

C61800-H04. Its machinability rates fair (35/100) against poor (30/100) for C61800-HR50; for welding the order is C61800-HR50 first (very good, 70/100) then C61800-H04 (good, 60/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in C61800-H04 and C61800-HR50 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.