C54400-H10 and C54400-O60 are two conditions of the same copper alloy grade, C54400: H10 (extra spring hard) versus O60 (soft annealed). The chemistry is identical, so every difference below comes from the condition. C54400-H10 is the stronger of the two: yield strength 565 MPa (81.9 ksi) against 131 MPa (19 ksi) for C54400-O60, about 4.3 times as much; tensile strength follows at 605 MPa (87.7 ksi) vs 310 MPa (45 ksi). In exchange, C54400-O60 is the more ductile: elongation 48% versus 3% for C54400-H10, and C54400-H10 is harder (190 HB vs 65 HB). C54400-H10 is stiffer (110 GPa vs 103 GPa) and C54400-O60 runs hotter in service (200°C vs 150°C continuous).

C54400-H10Choose it when strength drives the design.

C54400-O60Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C54400-H10 vs C54400-O60: properties

C54400-H10C54400-O60

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

110 GPa16 Msi
103 GPa14.9 Msi

Shear Modulus

41 GPa5.9 Msi
39 GPa5.7 Msi

Tensile Strength (Ultimate)

605 MPa87.7 ksi
310 MPa45 ksi

Yield Strength (0.2% offset)

565 MPa81.9 ksi
131 MPa19 ksi

Elongation at Break

3%
48%

Shear Strength

350 MPa50.8 ksi
210 MPa30.5 ksi

Fatigue Strength (Endurance Limit)

210 MPa30.5 ksi
140 MPa20.3 ksi

Hardness, Brinell

190 HB
65 HB

Hardness, Rockwell B

96 HRB
45 HRB

Hardness, Vickers

205 HV
160 HV

Same in both: Bulk Modulus 105 GPa15.2 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.89 g/cm³0.32 lb/in³ · Melting Point (Solidus) 854°C1,569 °F · Liquidus Temperature 1,000°C1,832 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

150°C302 °F
200°C392 °F

Same in both: Thermal Conductivity 87 W/m·K50.3 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.3 µm/m·K9.6 µin/in·°F · Latent Heat of Fusion 170 J/g73.1 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

18 % IACS
19 % IACS

Electrical Resistivity

9.6×10⁻⁸ Ω·m3.78 µΩ·in
9.1×10⁻⁸ Ω·m3.58 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

60 / 100
63 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

80 / 100
78 / 100

Weldability

20 / 100
25 / 100

Formability (cold)

15 / 100
88 / 100

Brazeability / Solderability

75 / 100
80 / 100

Polishability

75 / 100
70 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 80%

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

57 MJ/kg24,506 BTU/lb
55 MJ/kg23,646 BTU/lb

Embodied Carbon (primary production)

3.7 kg CO₂/kg
3.6 kg CO₂/kg

Same in both: Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC54400

C54400-H10 vs C54400-O60 — frequently asked

Is C54400-H10 stronger than C54400-O60?

Yes. C54400-H10 has a typical yield strength of 565 MPa (81.9 ksi) against 131 MPa (19 ksi) for C54400-O60 — about 4.3 times as much. Tensile strength is 605 MPa (87.7 ksi) vs 310 MPa (45 ksi).

Which condition does FabDigit quote by default, H10 or O60?

H04 is the default C54400 condition in the FabDigit quote flow (neither H10 nor O60). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, C54400-H10 or C54400-O60?

C54400-O60. Its weldability rates poor (25/100) against poor (20/100) for C54400-H10.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C54400-H10 and C54400-O60 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.