FabDigitFabDigit

Copper Alloy C49300-H02 vs C49300-H04

Copper Alloy · C49300 temper comparison

C49300-H02 and C49300-H04 are two conditions of the same copper alloy grade, C49300: H02 (half hard) versus H04 (full hard). The chemistry is identical, so every difference below comes from the condition. C49300-H04 is the stronger of the two: yield strength 420 MPa (60.9 ksi) against 310 MPa (45 ksi) for C49300-H02, about 35% more; tensile strength follows at 520 MPa (75.4 ksi) vs 440 MPa (63.8 ksi). In exchange, C49300-H02 is the more ductile: elongation 18% versus 8% for C49300-H04, and C49300-H04 is harder (155 HB vs 125 HB). C49300-H02 runs hotter in service (200°C vs 150°C continuous).

C49300-H02Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C49300-H04Choose it when strength drives the design.

C49300-H02 vs C49300-H04: properties

C49300-H02C49300-H04

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

440 MPa63.8 ksi
520 MPa75.4 ksi

Yield Strength (0.2% offset)

310 MPa45 ksi
420 MPa60.9 ksi

Elongation at Break

18%
8%

Shear Strength

290 MPa42.1 ksi
330 MPa47.9 ksi

Fatigue Strength (Endurance Limit)

140 MPa20.3 ksi
155 MPa22.5 ksi

Charpy V-Notch Impact (RT)

20 J14.8 ft·lbf
12 J8.9 ft·lbf

Hardness, Brinell

125 HB
155 HB

Hardness, Rockwell B

65 HRB
78 HRB

Hardness, Vickers

130 HV
165 HV

Same in both: Elastic (Young's) Modulus 103 GPa14.9 Msi · Shear Modulus 38 GPa5.5 Msi · Bulk Modulus 112 GPa16.2 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.5 g/cm³0.31 lb/in³ · Melting Point (Solidus) 885°C1,625 °F · Liquidus Temperature 920°C1,688 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

200°C392 °F
150°C302 °F

Same in both: Thermal Conductivity 110 W/m·K63.6 BTU/hr·ft·°F · Specific Heat Capacity 380 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 20.5 µm/m·K11.4 µin/in·°F · Latent Heat of Fusion 175 J/g75.2 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

26 % IACS
25 % IACS

Same in both: Electrical Resistivity 6.6×10⁻⁸ Ω·m2.6 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

66 / 100
63 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

88 / 100
90 / 100

Formability (cold)

40 / 100
22 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 250% · Weldability 30 / 100 · Castability 55 / 100 · Brazeability / Solderability 88 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 45 MJ/kg19,347 BTU/lb · Embodied Carbon (primary production) 3.1 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC49300

C49300-H02 vs C49300-H04 — frequently asked

Is C49300-H04 stronger than C49300-H02?

Yes. C49300-H04 has a typical yield strength of 420 MPa (60.9 ksi) against 310 MPa (45 ksi) for C49300-H02 — about 35% more. Tensile strength is 520 MPa (75.4 ksi) vs 440 MPa (63.8 ksi).

Which condition does FabDigit quote by default, H02 or H04?

H02 is the default C49300 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C49300-H02 over C49300-H04?

Pick C49300-H02 when the part is bent, formed or impact-loaded, or when the part sees heat. Pick C49300-H04 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C49300-H02 and C49300-H04 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.