FabDigitFabDigit

Copper Alloy C49300-H01 vs C49300-O61

Copper Alloy · C49300 temper comparison

C49300-H01 and C49300-O61 are two conditions of the same copper alloy grade, C49300: H01 (quarter hard) versus O61 (annealed). The chemistry is identical, so every difference below comes from the condition. C49300-H01 is the stronger of the two: yield strength 240 MPa (34.8 ksi) against 120 MPa (17.4 ksi) for C49300-O61, about 100% more; tensile strength follows at 400 MPa (58 ksi) vs 340 MPa (49.3 ksi). In exchange, C49300-O61 is the more ductile: elongation 45% versus 25% for C49300-H01, and C49300-H01 is harder (105 HB vs 65 HB). C49300-O61 runs hotter in service (200°C vs 180°C continuous).

C49300-H01Choose it when strength drives the design.

C49300-O61Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C49300-H01 vs C49300-O61: properties

C49300-H01C49300-O61

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

400 MPa58 ksi
340 MPa49.3 ksi

Yield Strength (0.2% offset)

240 MPa34.8 ksi
120 MPa17.4 ksi

Elongation at Break

25%
45%

Shear Strength

265 MPa38.4 ksi
230 MPa33.4 ksi

Fatigue Strength (Endurance Limit)

125 MPa18.1 ksi
105 MPa15.2 ksi

Hardness, Brinell

105 HB
65 HB

Hardness, Rockwell B

57 HRB
30 HRB

Hardness, Vickers

110 HV
130 HV

Same in both: Elastic (Young's) Modulus 103 GPa14.9 Msi · Shear Modulus 38 GPa5.5 Msi · Bulk Modulus 112 GPa16.2 Msi · Poisson's Ratio 0.34 · Charpy V-Notch Impact (RT) 30 J22.1 ft·lbf

Physical

Density and transition temperatures.

Same in both: Density 8.5 g/cm³0.31 lb/in³ · Melting Point (Solidus) 885°C1,625 °F · Liquidus Temperature 920°C1,688 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

180°C356 °F
200°C392 °F

Same in both: Thermal Conductivity 110 W/m·K63.6 BTU/hr·ft·°F · Specific Heat Capacity 380 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 20.5 µm/m·K11.4 µin/in·°F · Latent Heat of Fusion 175 J/g75.2 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

26 % IACS
27 % IACS

Same in both: Electrical Resistivity 6.6×10⁻⁸ Ω·m2.6 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

66 / 100
68 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

86 / 100
80 / 100

Machinability Rating (AISI 1212 = 100 %)

240%
250%

Formability (cold)

55 / 100
75 / 100

Same in both: Weldability 30 / 100 · Castability 55 / 100 · Brazeability / Solderability 88 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 45 MJ/kg19,347 BTU/lb · Embodied Carbon (primary production) 3.1 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC49300

C49300-H01 vs C49300-O61 — frequently asked

Is C49300-H01 stronger than C49300-O61?

Yes. C49300-H01 has a typical yield strength of 240 MPa (34.8 ksi) against 120 MPa (17.4 ksi) for C49300-O61 — about 100% more. Tensile strength is 400 MPa (58 ksi) vs 340 MPa (49.3 ksi).

Which condition does FabDigit quote by default, H01 or O61?

H02 is the default C49300 condition in the FabDigit quote flow (neither H01 nor O61). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C49300-H01 or C49300-O61?

C49300-H01. Its machinability rates excellent (86/100) against very good (80/100) for C49300-O61.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C49300-H01 and C49300-O61 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.