FabDigitFabDigit

Copper Alloy C48200-H04 vs C48200-M11

Copper Alloy · C48200 temper comparison

C48200-H04 and C48200-M11 are two conditions of the same copper alloy grade, C48200: H04 (full hard) versus M11 (as forged and quenched). The chemistry is identical, so every difference below comes from the condition. C48200-H04 is the stronger of the two: yield strength 400 MPa (58 ksi) against 205 MPa (29.7 ksi) for C48200-M11, about 95% more; tensile strength follows at 517 MPa (75 ksi) vs 448 MPa (65 ksi). In exchange, C48200-M11 is the more ductile: elongation 30% versus 15% for C48200-H04, and C48200-H04 is harder (160 HB vs 115 HB).

C48200-H04Choose it when strength drives the design.

C48200-M11Choose it when the part is bent, formed or impact-loaded.

C48200-H04 vs C48200-M11: properties

C48200-H04C48200-M11

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

517 MPa75 ksi
448 MPa65 ksi

Yield Strength (0.2% offset)

400 MPa58 ksi
205 MPa29.7 ksi

Elongation at Break

15%
30%

Reduction in Area

30%
38%

Shear Strength

330 MPa47.9 ksi
290 MPa42.1 ksi

Fatigue Strength (Endurance Limit)

160 MPa23.2 ksi
152 MPa22 ksi

Charpy V-Notch Impact (RT)

30 J22.1 ft·lbf
25 J18.4 ft·lbf

Hardness, Brinell

160 HB
115 HB

Hardness, Rockwell B

85 HRB
65 HRB

Hardness, Vickers

105 HV
120 HV

Same in both: Elastic (Young's) Modulus 100 GPa14.5 Msi · Shear Modulus 37 GPa5.4 Msi · Bulk Modulus 110 GPa16 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.44 g/cm³0.3 lb/in³ · Melting Point (Solidus) 885°C1,625 °F · Liquidus Temperature 900°C1,652 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

116 W/m·K67 BTU/hr·ft·°F
114 W/m·K65.9 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21.2 µm/m·K11.8 µin/in·°F · Latent Heat of Fusion 170 J/g73.1 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

26 % IACS
25 % IACS

Electrical Resistivity

6.6×10⁻⁸ Ω·m2.6 µΩ·in
6.9×10⁻⁸ Ω·m2.72 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

62 / 100
60 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.3 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

75 / 100
70 / 100

Machinability Rating (AISI 1212 = 100 %)

75%
70%

Formability (cold)

15 / 100
35 / 100

Same in both: Weldability 25 / 100 · Castability 45 / 100 · Brazeability / Solderability 85 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 53 MJ/kg22,786 BTU/lb · Embodied Carbon (primary production) 3.2 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 60%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC48200

C48200-H04 vs C48200-M11 — frequently asked

Is C48200-H04 stronger than C48200-M11?

Yes. C48200-H04 has a typical yield strength of 400 MPa (58 ksi) against 205 MPa (29.7 ksi) for C48200-M11 — about 95% more. Tensile strength is 517 MPa (75 ksi) vs 448 MPa (65 ksi).

Which condition does FabDigit quote by default, H04 or M11?

M30 is the default C48200 condition in the FabDigit quote flow (neither H04 nor M11). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C48200-H04 or C48200-M11?

C48200-H04, by a small margin. Both rate very good for machinability — 75/100 against 70/100 for C48200-M11.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C48200-H04 and C48200-M11 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.