FabDigitFabDigit

Copper Alloy C48200-H02 vs C48200-M30

Copper Alloy · C48200 temper comparison

C48200-H02 and C48200-M30 are two conditions of the same copper alloy grade, C48200: H02 (half hard) versus M30 (as hot extruded). The chemistry is identical, so every difference below comes from the condition. C48200-H02 is the stronger of the two: yield strength 345 MPa (50 ksi) against 172 MPa (24.9 ksi) for C48200-M30, about 101% more; tensile strength follows at 483 MPa (70.1 ksi) vs 379 MPa (55 ksi). In exchange, C48200-M30 is the more ductile: elongation 40% versus 20% for C48200-H02, and C48200-H02 is harder (140 HB vs 100 HB).

C48200-H02Choose it when strength drives the design.

C48200-M30Choose it when the part is bent, formed or impact-loaded.

C48200-H02 vs C48200-M30: properties

C48200-H02C48200-M30

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

483 MPa70.1 ksi
379 MPa55 ksi

Yield Strength (0.2% offset)

345 MPa50 ksi
172 MPa24.9 ksi

Elongation at Break

20%
40%

Reduction in Area

35%
45%

Shear Strength

310 MPa45 ksi
275 MPa39.9 ksi

Fatigue Strength (Endurance Limit)

152 MPa22 ksi
138 MPa20 ksi

Hardness, Brinell

140 HB
100 HB

Hardness, Rockwell B

78 HRB
55 HRB

Same in both: Elastic (Young's) Modulus 100 GPa14.5 Msi · Shear Modulus 37 GPa5.4 Msi · Bulk Modulus 110 GPa16 Msi · Poisson's Ratio 0.34 · Charpy V-Notch Impact (RT) 30 J22.1 ft·lbf · Hardness, Vickers 105 HV

Physical

Density and transition temperatures.

Same in both: Density 8.44 g/cm³0.3 lb/in³ · Melting Point (Solidus) 885°C1,625 °F · Liquidus Temperature 900°C1,652 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 116 W/m·K67 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21.2 µm/m·K11.8 µin/in·°F · Latent Heat of Fusion 170 J/g73.1 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 26 % IACS · Electrical Resistivity 6.6×10⁻⁸ Ω·m2.6 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.3 V · Corrosion Resistance 62 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

75 / 100
70 / 100

Machinability Rating (AISI 1212 = 100 %)

75%
70%

Formability (cold)

25 / 100
45 / 100

Same in both: Weldability 25 / 100 · Castability 45 / 100 · Brazeability / Solderability 85 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 53 MJ/kg22,786 BTU/lb · Embodied Carbon (primary production) 3.2 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 60%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC48200

C48200-H02 vs C48200-M30 — frequently asked

Is C48200-H02 stronger than C48200-M30?

Yes. C48200-H02 has a typical yield strength of 345 MPa (50 ksi) against 172 MPa (24.9 ksi) for C48200-M30 — about 101% more. Tensile strength is 483 MPa (70.1 ksi) vs 379 MPa (55 ksi).

Which condition does FabDigit quote by default, H02 or M30?

M30 is the default C48200 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C48200-H02 or C48200-M30?

C48200-H02, by a small margin. Both rate very good for machinability — 75/100 against 70/100 for C48200-M30.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C48200-H02 and C48200-M30 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.