FabDigitFabDigit

Copper Alloy C43400-H01 vs C43400-H04

Copper Alloy · C43400 temper comparison

C43400-H01 and C43400-H04 are two conditions of the same copper alloy grade, C43400: H01 (quarter hard) versus H04 (full hard). The chemistry is identical, so every difference below comes from the condition. C43400-H04 is the stronger of the two: yield strength 475 MPa (68.9 ksi) against 310 MPa (45 ksi) for C43400-H01, about 53% more; tensile strength follows at 545 MPa (79 ksi) vs 400 MPa (58 ksi). In exchange, C43400-H01 is the more ductile: elongation 25% versus 5% for C43400-H04, and C43400-H04 is harder (180 HV vs 125 HV). C43400-H01 runs hotter in service (180°C vs 150°C continuous).

C43400-H01Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C43400-H04Choose it when strength drives the design.

C43400-H01 vs C43400-H04: properties

C43400-H01C43400-H04

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

400 MPa58 ksi
545 MPa79 ksi

Yield Strength (0.2% offset)

310 MPa45 ksi
475 MPa68.9 ksi

Elongation at Break

25%
5%

Shear Strength

265 MPa38.4 ksi
320 MPa46.4 ksi

Fatigue Strength (Endurance Limit)

150 MPa21.8 ksi
170 MPa24.7 ksi

Hardness, Rockwell B

70 HRB
87 HRB

Hardness, Vickers

125 HV
180 HV

Same in both: Elastic (Young's) Modulus 110 GPa16 Msi · Shear Modulus 41 GPa5.9 Msi · Bulk Modulus 112 GPa16.2 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.75 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,000°C1,832 °F · Liquidus Temperature 1,030°C1,886 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

180°C356 °F
150°C302 °F

Same in both: Thermal Conductivity 121 W/m·K69.9 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 19.8 µm/m·K11 µin/in·°F · Latent Heat of Fusion 195 J/g83.8 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 26 % IACS · Electrical Resistivity 6.6×10⁻⁸ Ω·m2.6 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V · Corrosion Resistance 62 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability Rating (AISI 1212 = 100 %)

28%
33%

Formability (cold)

80 / 100
45 / 100

Same in both: Machinability 32 / 100 · Weldability 55 / 100 · Brazeability / Solderability 90 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 62 MJ/kg26,655 BTU/lb · Embodied Carbon (primary production) 4 kg CO₂/kg · Embodied Water 320 L/kg38.3 gal/lb · Typical Recycled Content 45%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC43400

C43400-H01 vs C43400-H04 — frequently asked

Is C43400-H04 stronger than C43400-H01?

Yes. C43400-H04 has a typical yield strength of 475 MPa (68.9 ksi) against 310 MPa (45 ksi) for C43400-H01 — about 53% more. Tensile strength is 545 MPa (79 ksi) vs 400 MPa (58 ksi).

Which condition does FabDigit quote by default, H01 or H04?

H02 is the default C43400 condition in the FabDigit quote flow (neither H01 nor H04). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C43400-H01 over C43400-H04?

Pick C43400-H01 when the part is bent, formed or impact-loaded, or when the part sees heat. Pick C43400-H04 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C43400-H01 and C43400-H04 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.