FabDigitFabDigit

Copper Alloy C43000-H02 vs C43000-H10

Copper Alloy · C43000 temper comparison

C43000-H02 and C43000-H10 are two conditions of the same copper alloy grade, C43000: H02 (half hard) versus H10 (extra spring hard). The chemistry is identical, so every difference below comes from the condition. C43000-H10 is the stronger of the two: yield strength 620 MPa (89.9 ksi) against 385 MPa (55.8 ksi) for C43000-H02, about 61% more; tensile strength follows at 680 MPa (98.6 ksi) vs 455 MPa (66 ksi). In exchange, C43000-H02 is the more ductile: elongation 20% versus 2% for C43000-H10, and C43000-H10 is harder (215 HV vs 140 HV). C43000-H02 runs hotter in service (150°C vs 120°C continuous).

C43000-H02Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C43000-H10Choose it when strength drives the design.

C43000-H02 vs C43000-H10: properties

C43000-H02C43000-H10

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

455 MPa66 ksi
680 MPa98.6 ksi

Yield Strength (0.2% offset)

385 MPa55.8 ksi
620 MPa89.9 ksi

Elongation at Break

20%
2%

Shear Strength

295 MPa42.8 ksi
405 MPa58.7 ksi

Fatigue Strength (Endurance Limit)

180 MPa26.1 ksi
225 MPa32.6 ksi

Hardness, Rockwell B

72 HRB
93 HRB

Hardness, Vickers

140 HV
215 HV

Same in both: Elastic (Young's) Modulus 110 GPa16 Msi · Shear Modulus 41 GPa5.9 Msi · Bulk Modulus 115 GPa16.7 Msi · Poisson's Ratio 0.33 · Hardness, Brinell 130 HB

Physical

Density and transition temperatures.

Same in both: Density 8.53 g/cm³0.31 lb/in³ · Melting Point (Solidus) 900°C1,652 °F · Liquidus Temperature 1,000°C1,832 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

150°C302 °F
120°C248 °F

Same in both: Thermal Conductivity 110 W/m·K63.6 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 19.1 µm/m·K10.6 µin/in·°F · Latent Heat of Fusion 200 J/g86 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

25 % IACS
24 % IACS

Same in both: Electrical Resistivity 6.9×10⁻⁸ Ω·m2.72 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.27 V · Corrosion Resistance 60 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

32 / 100
40 / 100

Formability (cold)

70 / 100
18 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 30% · Weldability 55 / 100 · Castability 35 / 100 · Brazeability / Solderability 90 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 60 MJ/kg25,795 BTU/lb · Embodied Carbon (primary production) 3.7 kg CO₂/kg · Embodied Water 260 L/kg31.2 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC43000

C43000-H02 vs C43000-H10 — frequently asked

Is C43000-H10 stronger than C43000-H02?

Yes. C43000-H10 has a typical yield strength of 620 MPa (89.9 ksi) against 385 MPa (55.8 ksi) for C43000-H02 — about 61% more. Tensile strength is 680 MPa (98.6 ksi) vs 455 MPa (66 ksi).

Which condition does FabDigit quote by default, H02 or H10?

H02 is the default C43000 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C43000-H02 or C43000-H10?

C43000-H10. Its machinability rates fair (40/100) against poor (32/100) for C43000-H02.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C43000-H02 and C43000-H10 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.