FabDigitFabDigit

Copper Alloy C42600-H01 vs C42600-H10

Copper Alloy · C42600 temper comparison

C42600-H01 and C42600-H10 are two conditions of the same copper alloy grade, C42600: H01 (quarter hard) versus H10 (extra spring hard). The chemistry is identical, so every difference below comes from the condition. C42600-H10 is the stronger of the two: yield strength 580 MPa (84.1 ksi) against 300 MPa (43.5 ksi) for C42600-H01, about 93% more; tensile strength follows at 620 MPa (89.9 ksi) vs 400 MPa (58 ksi). In exchange, C42600-H01 is the more ductile: elongation 25% versus 2% for C42600-H10, and C42600-H10 is harder (185 HB vs 110 HB). C42600-H01 runs hotter in service (160°C vs 120°C continuous). On the shop floor, C42600-H10 machines more easily (fair vs poor).

C42600-H01Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C42600-H10Choose it when strength drives the design, or when the part is machined in volume.

C42600-H01 vs C42600-H10: properties

C42600-H01C42600-H10

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

400 MPa58 ksi
620 MPa89.9 ksi

Yield Strength (0.2% offset)

300 MPa43.5 ksi
580 MPa84.1 ksi

Elongation at Break

25%
2%

Shear Strength

275 MPa39.9 ksi
390 MPa56.6 ksi

Fatigue Strength (Endurance Limit)

165 MPa23.9 ksi
220 MPa31.9 ksi

Hardness, Brinell

110 HB
185 HB

Hardness, Rockwell B

62 HRB
91 HRB

Hardness, Vickers

115 HV
195 HV

Same in both: Elastic (Young's) Modulus 110 GPa16 Msi · Shear Modulus 41 GPa5.9 Msi · Bulk Modulus 115 GPa16.7 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 8.78 g/cm³0.32 lb/in³ · Melting Point (Solidus) 940°C1,724 °F · Liquidus Temperature 1,025°C1,877 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

160°C320 °F
120°C248 °F

Same in both: Thermal Conductivity 120 W/m·K69.3 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 20.2 µm/m·K11.2 µin/in·°F · Latent Heat of Fusion 190 J/g81.7 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

31 % IACS
29 % IACS

Same in both: Electrical Resistivity 5.6×10⁻⁸ Ω·m2.2 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V · Corrosion Resistance 58 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

33 / 100
44 / 100

Formability (cold)

80 / 100
25 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 30% · Weldability 40 / 100 · Brazeability / Solderability 88 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 60 MJ/kg25,795 BTU/lb · Embodied Carbon (primary production) 4 kg CO₂/kg · Embodied Water 260 L/kg31.2 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC42600

C42600-H01 vs C42600-H10 — frequently asked

Is C42600-H10 stronger than C42600-H01?

Yes. C42600-H10 has a typical yield strength of 580 MPa (84.1 ksi) against 300 MPa (43.5 ksi) for C42600-H01 — about 93% more. Tensile strength is 620 MPa (89.9 ksi) vs 400 MPa (58 ksi).

Which condition does FabDigit quote by default, H01 or H10?

H02 is the default C42600 condition in the FabDigit quote flow (neither H01 nor H10). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C42600-H01 or C42600-H10?

C42600-H10. Its machinability rates fair (44/100) against poor (33/100) for C42600-H01.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C42600-H01 and C42600-H10 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.