FabDigitFabDigit

Copper Alloy C40500-H01 vs C40500-H04

Copper Alloy · C40500 temper comparison

C40500-H01 and C40500-H04 are two conditions of the same copper alloy grade, C40500: H01 (quarter hard) versus H04 (full hard). The chemistry is identical, so every difference below comes from the condition. C40500-H04 is the stronger of the two: yield strength 400 MPa (58 ksi) against 275 MPa (39.9 ksi) for C40500-H01, about 45% more; tensile strength follows at 455 MPa (66 ksi) vs 330 MPa (47.9 ksi). In exchange, C40500-H01 is the more ductile: elongation 28% versus 5% for C40500-H04, and C40500-H04 is harder (145 HB vs 100 HB). C40500-H01 runs hotter in service (200°C vs 175°C continuous).

C40500-H01Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C40500-H04Choose it when strength drives the design.

C40500-H01 vs C40500-H04: properties

C40500-H01C40500-H04

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

330 MPa47.9 ksi
455 MPa66 ksi

Yield Strength (0.2% offset)

275 MPa39.9 ksi
400 MPa58 ksi

Elongation at Break

28%
5%

Shear Strength

225 MPa32.6 ksi
280 MPa40.6 ksi

Fatigue Strength (Endurance Limit)

135 MPa19.6 ksi
165 MPa23.9 ksi

Hardness, Brinell

100 HB
145 HB

Hardness, Rockwell B

55 HRB
78 HRB

Hardness, Vickers

105 HV
152 HV

Same in both: Elastic (Young's) Modulus 117 GPa17 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 118 GPa17.1 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 8.86 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,035°C1,895 °F · Liquidus Temperature 1,055°C1,931 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

200°C392 °F
175°C347 °F

Same in both: Thermal Conductivity 170 W/m·K98.2 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18.4 µm/m·K10.2 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

40 % IACS
39 % IACS

Same in both: Electrical Resistivity 4.3×10⁻⁸ Ω·m1.69 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V · Corrosion Resistance 66 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

20 / 100
26 / 100

Formability (cold)

78 / 100
42 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 20% · Weldability 40 / 100 · Castability 35 / 100 · Brazeability / Solderability 92 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 57 MJ/kg24,506 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 320 L/kg38.3 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC40500

C40500-H01 vs C40500-H04 — frequently asked

Is C40500-H04 stronger than C40500-H01?

Yes. C40500-H04 has a typical yield strength of 400 MPa (58 ksi) against 275 MPa (39.9 ksi) for C40500-H01 — about 45% more. Tensile strength is 455 MPa (66 ksi) vs 330 MPa (47.9 ksi).

Which condition does FabDigit quote by default, H01 or H04?

H02 is the default C40500 condition in the FabDigit quote flow (neither H01 nor H04). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C40500-H01 or C40500-H04?

C40500-H04, by a small margin. Both rate poor for machinability — 26/100 against 20/100 for C40500-H01.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C40500-H01 and C40500-H04 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.