FabDigitFabDigit

Copper Alloy C35300-H02 vs C35300-H04

Copper Alloy · C35300 temper comparison

C35300-H02 and C35300-H04 are two conditions of the same copper alloy grade, C35300: H02 (half hard) versus H04 (full hard). The chemistry is identical, so every difference below comes from the condition. C35300-H04 is the stronger of the two: yield strength 415 MPa (60.2 ksi) against 345 MPa (50 ksi) for C35300-H02, about 20% more; tensile strength follows at 480 MPa (69.6 ksi) vs 420 MPa (60.9 ksi). In exchange, C35300-H02 is the more ductile: elongation 20% versus 8% for C35300-H04, and C35300-H04 is harder (145 HB vs 115 HB).

C35300-H02Choose it when the part is bent, formed or impact-loaded.

C35300-H04Choose it when strength drives the design.

C35300-H02 vs C35300-H04: properties

C35300-H02C35300-H04

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

420 MPa60.9 ksi
480 MPa69.6 ksi

Yield Strength (0.2% offset)

345 MPa50 ksi
415 MPa60.2 ksi

Elongation at Break

20%
8%

Shear Strength

290 MPa42.1 ksi
315 MPa45.7 ksi

Fatigue Strength (Endurance Limit)

140 MPa20.3 ksi
150 MPa21.8 ksi

Hardness, Brinell

115 HB
145 HB

Hardness, Rockwell B

70 HRB
80 HRB

Hardness, Vickers

125 HV
152 HV

Same in both: Elastic (Young's) Modulus 97 GPa14.1 Msi · Shear Modulus 37 GPa5.4 Msi · Bulk Modulus 112 GPa16.2 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.47 g/cm³0.31 lb/in³ · Melting Point (Solidus) 888°C1,630 °F · Liquidus Temperature 899°C1,650 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 115 W/m·K66.4 BTU/hr·ft·°F · Specific Heat Capacity 380 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 20.3 µm/m·K11.3 µin/in·°F · Latent Heat of Fusion 160 J/g68.8 BTU/lb · Max Service Temperature (continuous) 150°C302 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

26 % IACS
25.5 % IACS

Electrical Resistivity

6.6×10⁻⁸ Ω·m2.6 µΩ·in
6.8×10⁻⁸ Ω·m2.68 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

45 / 100
43 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

70 / 100
72 / 100

Machinability Rating (AISI 1212 = 100 %)

180%
185%

Formability (cold)

55 / 100
35 / 100

Same in both: Weldability 15 / 100 · Brazeability / Solderability 70 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 58 MJ/kg24,936 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 220 L/kg26.4 gal/lb · Typical Recycled Content 45%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC35300

C35300-H02 vs C35300-H04 — frequently asked

Is C35300-H04 stronger than C35300-H02?

Yes. C35300-H04 has a typical yield strength of 415 MPa (60.2 ksi) against 345 MPa (50 ksi) for C35300-H02 — about 20% more. Tensile strength is 480 MPa (69.6 ksi) vs 420 MPa (60.9 ksi).

Which condition does FabDigit quote by default, H02 or H04?

H02 is the default C35300 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C35300-H02 over C35300-H04?

Pick C35300-H02 when the part is bent, formed or impact-loaded. Pick C35300-H04 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C35300-H02 and C35300-H04 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.