FabDigitFabDigit

Copper Alloy C35300-H01 vs C35300-H06

Copper Alloy · C35300 temper comparison

C35300-H01 and C35300-H06 are two conditions of the same copper alloy grade, C35300: H01 (quarter hard) versus H06 (extra hard). The chemistry is identical, so every difference below comes from the condition. C35300-H06 is the stronger of the two: yield strength 450 MPa (65.3 ksi) against 275 MPa (39.9 ksi) for C35300-H01, about 64% more; tensile strength follows at 520 MPa (75.4 ksi) vs 370 MPa (53.7 ksi). In exchange, C35300-H01 is the more ductile: elongation 30% versus 5% for C35300-H06, and C35300-H06 is harder (155 HB vs 95 HB).

C35300-H01Choose it when the part is bent, formed or impact-loaded.

C35300-H06Choose it when strength drives the design.

C35300-H01 vs C35300-H06: properties

C35300-H01C35300-H06

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

370 MPa53.7 ksi
520 MPa75.4 ksi

Yield Strength (0.2% offset)

275 MPa39.9 ksi
450 MPa65.3 ksi

Elongation at Break

30%
5%

Shear Strength

265 MPa38.4 ksi
330 MPa47.9 ksi

Fatigue Strength (Endurance Limit)

130 MPa18.9 ksi
155 MPa22.5 ksi

Hardness, Brinell

95 HB
155 HB

Hardness, Rockwell B

57 HRB
83 HRB

Hardness, Vickers

100 HV
163 HV

Same in both: Elastic (Young's) Modulus 97 GPa14.1 Msi · Shear Modulus 37 GPa5.4 Msi · Bulk Modulus 112 GPa16.2 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.47 g/cm³0.31 lb/in³ · Melting Point (Solidus) 888°C1,630 °F · Liquidus Temperature 899°C1,650 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 115 W/m·K66.4 BTU/hr·ft·°F · Specific Heat Capacity 380 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 20.3 µm/m·K11.3 µin/in·°F · Latent Heat of Fusion 160 J/g68.8 BTU/lb · Max Service Temperature (continuous) 150°C302 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

26 % IACS
25.5 % IACS

Electrical Resistivity

6.6×10⁻⁸ Ω·m2.6 µΩ·in
6.8×10⁻⁸ Ω·m2.68 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

45 / 100
42 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

68 / 100
74 / 100

Machinability Rating (AISI 1212 = 100 %)

175%
190%

Formability (cold)

65 / 100
25 / 100

Same in both: Weldability 15 / 100 · Brazeability / Solderability 70 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 58 MJ/kg24,936 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 220 L/kg26.4 gal/lb · Typical Recycled Content 45%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC35300

C35300-H01 vs C35300-H06 — frequently asked

Is C35300-H06 stronger than C35300-H01?

Yes. C35300-H06 has a typical yield strength of 450 MPa (65.3 ksi) against 275 MPa (39.9 ksi) for C35300-H01 — about 64% more. Tensile strength is 520 MPa (75.4 ksi) vs 370 MPa (53.7 ksi).

Which condition does FabDigit quote by default, H01 or H06?

H02 is the default C35300 condition in the FabDigit quote flow (neither H01 nor H06). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C35300-H01 or C35300-H06?

C35300-H06. Its machinability rates very good (74/100) against good (68/100) for C35300-H01.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C35300-H01 and C35300-H06 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.