FabDigitFabDigit

Copper Alloy C34500-H01 vs C34500-H04

Copper Alloy · C34500 temper comparison

C34500-H01 and C34500-H04 are two conditions of the same copper alloy grade, C34500: H01 (quarter hard) versus H04 (full hard). The chemistry is identical, so every difference below comes from the condition. C34500-H04 is the stronger of the two: yield strength 380 MPa (55.1 ksi) against 235 MPa (34.1 ksi) for C34500-H01, about 62% more; tensile strength follows at 470 MPa (68.2 ksi) vs 370 MPa (53.7 ksi). In exchange, C34500-H01 is the more ductile: elongation 30% versus 12% for C34500-H04, and C34500-H04 is harder (145 HB vs 100 HB).

C34500-H01Choose it when the part is bent, formed or impact-loaded.

C34500-H04Choose it when strength drives the design.

C34500-H01 vs C34500-H04: properties

C34500-H01C34500-H04

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

370 MPa53.7 ksi
470 MPa68.2 ksi

Yield Strength (0.2% offset)

235 MPa34.1 ksi
380 MPa55.1 ksi

Elongation at Break

30%
12%

Reduction in Area

52%
45%

Shear Strength

250 MPa36.3 ksi
300 MPa43.5 ksi

Fatigue Strength (Endurance Limit)

135 MPa19.6 ksi
160 MPa23.2 ksi

Charpy V-Notch Impact (RT)

38 J28 ft·lbf
22 J16.2 ft·lbf

Hardness, Brinell

100 HB
145 HB

Hardness, Rockwell B

62 HRB
82 HRB

Hardness, Vickers

108 HV
155 HV

Same in both: Elastic (Young's) Modulus 97 GPa14.1 Msi · Shear Modulus 37 GPa5.4 Msi · Bulk Modulus 115 GPa16.7 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.47 g/cm³0.31 lb/in³ · Melting Point (Solidus) 885°C1,625 °F · Liquidus Temperature 900°C1,652 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

180°C356 °F
170°C338 °F

Same in both: Thermal Conductivity 115 W/m·K66.4 BTU/hr·ft·°F · Specific Heat Capacity 380 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 20.5 µm/m·K11.4 µin/in·°F · Latent Heat of Fusion 170 J/g73.1 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 26 % IACS · Electrical Resistivity 6.6×10⁻⁸ Ω·m2.6 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V · Corrosion Resistance 52 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

88 / 100
90 / 100

Machinability Rating (AISI 1212 = 100 %)

85%
90%

Formability (cold)

55 / 100
25 / 100

Same in both: Weldability 15 / 100 · Brazeability / Solderability 85 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 58 MJ/kg24,936 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 55%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC34500

C34500-H01 vs C34500-H04 — frequently asked

Is C34500-H04 stronger than C34500-H01?

Yes. C34500-H04 has a typical yield strength of 380 MPa (55.1 ksi) against 235 MPa (34.1 ksi) for C34500-H01 — about 62% more. Tensile strength is 470 MPa (68.2 ksi) vs 370 MPa (53.7 ksi).

Which condition does FabDigit quote by default, H01 or H04?

H02 is the default C34500 condition in the FabDigit quote flow (neither H01 nor H04). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C34500-H01 over C34500-H04?

Pick C34500-H01 when the part is bent, formed or impact-loaded. Pick C34500-H04 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C34500-H01 and C34500-H04 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.