FabDigitFabDigit

Copper Alloy C31400-H02 vs C31400-H04

Copper Alloy · C31400 temper comparison

C31400-H02 and C31400-H04 are two conditions of the same copper alloy grade, C31400: H02 (half hard) versus H04 (full hard). The chemistry is identical, so every difference below comes from the condition. C31400-H04 is the stronger of the two: yield strength 340 MPa (49.3 ksi) against 240 MPa (34.8 ksi) for C31400-H02, about 42% more; tensile strength follows at 415 MPa (60.2 ksi) vs 345 MPa (50 ksi). In exchange, C31400-H02 is the more ductile: elongation 20% versus 10% for C31400-H04, and C31400-H04 is harder (125 HB vs 100 HB). C31400-H02 runs hotter in service (200°C vs 175°C continuous).

C31400-H02Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C31400-H04Choose it when strength drives the design.

C31400-H02 vs C31400-H04: properties

C31400-H02C31400-H04

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

345 MPa50 ksi
415 MPa60.2 ksi

Yield Strength (0.2% offset)

240 MPa34.8 ksi
340 MPa49.3 ksi

Elongation at Break

20%
10%

Reduction in Area

45%
35%

Shear Strength

230 MPa33.4 ksi
255 MPa37 ksi

Fatigue Strength (Endurance Limit)

125 MPa18.1 ksi
145 MPa21 ksi

Hardness, Brinell

100 HB
125 HB

Hardness, Rockwell B

60 HRB
72 HRB

Same in both: Elastic (Young's) Modulus 117 GPa17 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 118 GPa17.1 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.83 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,010°C1,850 °F · Liquidus Temperature 1,035°C1,895 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

200°C392 °F
175°C347 °F

Same in both: Thermal Conductivity 180 W/m·K104 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18.4 µm/m·K10.2 µin/in·°F · Latent Heat of Fusion 190 J/g81.7 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

42 % IACS
41 % IACS

Same in both: Electrical Resistivity 4.1×10⁻⁸ Ω·m1.61 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.27 V · Corrosion Resistance 62 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

80 / 100
82 / 100

Formability (cold)

70 / 100
40 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 130% · Weldability 25 / 100 · Castability 40 / 100 · Brazeability / Solderability 90 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 260 L/kg31.2 gal/lb · Typical Recycled Content 45%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC31400

C31400-H02 vs C31400-H04 — frequently asked

Is C31400-H04 stronger than C31400-H02?

Yes. C31400-H04 has a typical yield strength of 340 MPa (49.3 ksi) against 240 MPa (34.8 ksi) for C31400-H02 — about 42% more. Tensile strength is 415 MPa (60.2 ksi) vs 345 MPa (50 ksi).

Which condition does FabDigit quote by default, H02 or H04?

H02 is the default C31400 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C31400-H02 over C31400-H04?

Pick C31400-H02 when the part is bent, formed or impact-loaded, or when the part sees heat. Pick C31400-H04 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C31400-H02 and C31400-H04 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.