FabDigitFabDigit

Copper Alloy C24000-H01 vs C24000-H04

Copper Alloy · C24000 temper comparison

C24000-H01 and C24000-H04 are two conditions of the same copper alloy grade, C24000: H01 (quarter hard) versus H04 (full hard). The chemistry is identical, so every difference below comes from the condition. C24000-H04 is the stronger of the two: yield strength 415 MPa (60.2 ksi) against 230 MPa (33.4 ksi) for C24000-H01, about 80% more; tensile strength follows at 510 MPa (74 ksi) vs 340 MPa (49.3 ksi). In exchange, C24000-H01 is the more ductile: elongation 43% versus 8% for C24000-H04, and C24000-H04 is harder (150 HB vs 95 HB). C24000-H01 runs hotter in service (175°C vs 150°C continuous).

C24000-H01Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C24000-H04Choose it when strength drives the design.

C24000-H01 vs C24000-H04: properties

C24000-H01C24000-H04

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

340 MPa49.3 ksi
510 MPa74 ksi

Yield Strength (0.2% offset)

230 MPa33.4 ksi
415 MPa60.2 ksi

Elongation at Break

43%
8%

Shear Strength

240 MPa34.8 ksi
310 MPa45 ksi

Fatigue Strength (Endurance Limit)

115 MPa16.7 ksi
150 MPa21.8 ksi

Hardness, Brinell

95 HB
150 HB

Hardness, Vickers

105 HV
160 HV

Same in both: Elastic (Young's) Modulus 105 GPa15.2 Msi · Shear Modulus 39 GPa5.7 Msi · Bulk Modulus 112 GPa16.2 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.67 g/cm³0.31 lb/in³ · Melting Point (Solidus) 1,000°C1,832 °F · Liquidus Temperature 1,030°C1,886 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

175°C347 °F
150°C302 °F

Same in both: Thermal Conductivity 138 W/m·K79.7 BTU/hr·ft·°F · Specific Heat Capacity 375 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18.4 µm/m·K10.2 µin/in·°F · Latent Heat of Fusion 180 J/g77.4 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 32 % IACS · Electrical Resistivity 5.4×10⁻⁸ Ω·m2.13 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.26 V · Corrosion Resistance 60 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability Rating (AISI 1212 = 100 %)

30%
35%

Formability (cold)

80 / 100
38 / 100

Same in both: Machinability 32 / 100 · Weldability 45 / 100 · Castability 30 / 100 · Brazeability / Solderability 90 / 100 · Polishability 85 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 58 MJ/kg24,936 BTU/lb · Embodied Carbon (primary production) 4 kg CO₂/kg · Embodied Water 400 L/kg47.9 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC24000

C24000-H01 vs C24000-H04 — frequently asked

Is C24000-H04 stronger than C24000-H01?

Yes. C24000-H04 has a typical yield strength of 415 MPa (60.2 ksi) against 230 MPa (33.4 ksi) for C24000-H01 — about 80% more. Tensile strength is 510 MPa (74 ksi) vs 340 MPa (49.3 ksi).

Which condition does FabDigit quote by default, H01 or H04?

OS050 is the default C24000 condition in the FabDigit quote flow (neither H01 nor H04). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C24000-H01 over C24000-H04?

Pick C24000-H01 when the part is bent, formed or impact-loaded, or when the part sees heat. Pick C24000-H04 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C24000-H01 and C24000-H04 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.