FabDigitFabDigit

Copper Alloy C23400-H04 vs C23400-O61

Copper Alloy · C23400 temper comparison

C23400-H04 and C23400-O61 are two conditions of the same copper alloy grade, C23400: H04 (full hard) versus O61 (annealed). The chemistry is identical, so every difference below comes from the condition. C23400-H04 is the stronger of the two: yield strength 370 MPa (53.7 ksi) against 95 MPa (13.8 ksi) for C23400-O61, about 3.9 times as much; tensile strength follows at 430 MPa (62.4 ksi) vs 290 MPa (42.1 ksi). In exchange, C23400-O61 is the more ductile: elongation 48% versus 6% for C23400-H04, and C23400-H04 is harder (132 HB vs 58 HB). C23400-O61 runs hotter in service (250°C vs 150°C continuous).

C23400-H04Choose it when strength drives the design.

C23400-O61Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C23400-H04 vs C23400-O61: properties

C23400-H04C23400-O61

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

430 MPa62.4 ksi
290 MPa42.1 ksi

Yield Strength (0.2% offset)

370 MPa53.7 ksi
95 MPa13.8 ksi

Elongation at Break

6%
48%

Reduction in Area

48%
65%

Shear Strength

280 MPa40.6 ksi
205 MPa29.7 ksi

Fatigue Strength (Endurance Limit)

140 MPa20.3 ksi
95 MPa13.8 ksi

Hardness, Brinell

132 HB
58 HB

Hardness, Rockwell B

75 HRB
20 HRB

Hardness, Vickers

140 HV
62 HV

Same in both: Elastic (Young's) Modulus 112 GPa16.2 Msi · Shear Modulus 42 GPa6.1 Msi · Bulk Modulus 115 GPa16.7 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.72 g/cm³0.32 lb/in³ · Melting Point (Solidus) 990°C1,814 °F · Liquidus Temperature 1,015°C1,859 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

150°C302 °F
250°C482 °F

Same in both: Thermal Conductivity 150 W/m·K86.7 BTU/hr·ft·°F · Specific Heat Capacity 380 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 19.1 µm/m·K10.6 µin/in·°F · Latent Heat of Fusion 190 J/g81.7 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 34 % IACS · Electrical Resistivity 5.07×10⁻⁸ Ω·m2 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

54 / 100
62 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.29 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

35 / 100
26 / 100

Machinability Rating (AISI 1212 = 100 %)

33%
25%

Formability (cold)

32 / 100
95 / 100

Same in both: Weldability 45 / 100 · Brazeability / Solderability 95 / 100 · Polishability 85 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 57 MJ/kg24,506 BTU/lb · Embodied Carbon (primary production) 3.5 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC23400

C23400-H04 vs C23400-O61 — frequently asked

Is C23400-H04 stronger than C23400-O61?

Yes. C23400-H04 has a typical yield strength of 370 MPa (53.7 ksi) against 95 MPa (13.8 ksi) for C23400-O61 — about 3.9 times as much. Tensile strength is 430 MPa (62.4 ksi) vs 290 MPa (42.1 ksi).

Which condition does FabDigit quote by default, H04 or O61?

H02 is the default C23400 condition in the FabDigit quote flow (neither H04 nor O61). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C23400-H04 or C23400-O61?

C23400-H04. Its machinability rates fair (35/100) against poor (26/100) for C23400-O61.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C23400-H04 and C23400-O61 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.