FabDigitFabDigit

Copper Alloy C23000-H03 vs C23000-H06

Copper Alloy · C23000 temper comparison

C23000-H03 and C23000-H06 are two conditions of the same copper alloy grade, C23000: H03 (three-quarter hard) versus H06 (extra hard). The chemistry is identical, so every difference below comes from the condition. C23000-H06 is the stronger of the two: yield strength 415 MPa (60.2 ksi) against 325 MPa (47.1 ksi) for C23000-H03, about 28% more; tensile strength follows at 490 MPa (71.1 ksi) vs 380 MPa (55.1 ksi). In exchange, C23000-H03 is the more ductile: elongation 12% versus 4% for C23000-H06, and C23000-H06 is harder (140 HB vs 105 HB).

C23000-H03Choose it when the part is bent, formed or impact-loaded.

C23000-H06Choose it when strength drives the design.

C23000-H03 vs C23000-H06: properties

C23000-H03C23000-H06

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

380 MPa55.1 ksi
490 MPa71.1 ksi

Yield Strength (0.2% offset)

325 MPa47.1 ksi
415 MPa60.2 ksi

Elongation at Break

12%
4%

Reduction in Area

35%
20%

Shear Strength

250 MPa36.3 ksi
285 MPa41.3 ksi

Fatigue Strength (Endurance Limit)

135 MPa19.6 ksi
150 MPa21.8 ksi

Charpy V-Notch Impact (RT)

28 J20.7 ft·lbf
18 J13.3 ft·lbf

Hardness, Brinell

105 HB
140 HB

Same in both: Elastic (Young's) Modulus 117 GPa17 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 120 GPa17.4 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.75 g/cm³0.32 lb/in³ · Melting Point (Solidus) 990°C1,814 °F · Liquidus Temperature 1,025°C1,877 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 159 W/m·K91.9 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18.7 µm/m·K10.4 µin/in·°F · Latent Heat of Fusion 195 J/g83.8 BTU/lb · Max Service Temperature (continuous) 150°C302 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

37 % IACS
36 % IACS

Electrical Resistivity

4.66×10⁻⁸ Ω·m1.83 µΩ·in
4.79×10⁻⁸ Ω·m1.89 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

60 / 100
58 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.27 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

36 / 100
38 / 100

Weldability

50 / 100
48 / 100

Formability (cold)

55 / 100
28 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 30% · Castability 40 / 100 · Brazeability / Solderability 92 / 100 · Polishability 88 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 62 MJ/kg26,655 BTU/lb · Embodied Carbon (primary production) 4 kg CO₂/kg · Embodied Water 260 L/kg31.2 gal/lb · Typical Recycled Content 45%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC23000

C23000-H03 vs C23000-H06 — frequently asked

Is C23000-H06 stronger than C23000-H03?

Yes. C23000-H06 has a typical yield strength of 415 MPa (60.2 ksi) against 325 MPa (47.1 ksi) for C23000-H03 — about 28% more. Tensile strength is 490 MPa (71.1 ksi) vs 380 MPa (55.1 ksi).

Which condition does FabDigit quote by default, H03 or H06?

OS050 is the default C23000 condition in the FabDigit quote flow (neither H03 nor H06). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C23000-H03 over C23000-H06?

Pick C23000-H03 when the part is bent, formed or impact-loaded. Pick C23000-H06 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C23000-H03 and C23000-H06 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.