FabDigitFabDigit

Copper Alloy C23000-H02 vs C23000-H04

Copper Alloy · C23000 temper comparison

C23000-H02 and C23000-H04 are two conditions of the same copper alloy grade, C23000: H02 (half hard) versus H04 (full hard). The chemistry is identical, so every difference below comes from the condition. C23000-H04 is the stronger of the two: yield strength 360 MPa (52.2 ksi) against 275 MPa (39.9 ksi) for C23000-H02, about 31% more; tensile strength follows at 420 MPa (60.9 ksi) vs 340 MPa (49.3 ksi). In exchange, C23000-H02 is the more ductile: elongation 25% versus 5% for C23000-H04, and C23000-H04 is harder (120 HB vs 88 HB).

C23000-H02Choose it when the part is bent, formed or impact-loaded.

C23000-H04Choose it when strength drives the design.

C23000-H02 vs C23000-H04: properties

C23000-H02C23000-H04

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

340 MPa49.3 ksi
420 MPa60.9 ksi

Yield Strength (0.2% offset)

275 MPa39.9 ksi
360 MPa52.2 ksi

Elongation at Break

25%
5%

Shear Strength

235 MPa34.1 ksi
265 MPa38.4 ksi

Fatigue Strength (Endurance Limit)

125 MPa18.1 ksi
145 MPa21 ksi

Hardness, Brinell

88 HB
120 HB

Same in both: Elastic (Young's) Modulus 117 GPa17 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 120 GPa17.4 Msi · Poisson's Ratio 0.34 · Reduction in Area 65% · Charpy V-Notch Impact (RT) 60 J44.3 ft·lbf

Physical

Density and transition temperatures.

Same in both: Density 8.75 g/cm³0.32 lb/in³ · Melting Point (Solidus) 990°C1,814 °F · Liquidus Temperature 1,025°C1,877 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 159 W/m·K91.9 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18.7 µm/m·K10.4 µin/in·°F · Latent Heat of Fusion 195 J/g83.8 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

37 % IACS
36 % IACS

Same in both: Electrical Resistivity 4.66×10⁻⁸ Ω·m1.83 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.27 V · Corrosion Resistance 63 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

34 / 100
38 / 100

Formability (cold)

70 / 100
40 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 30% · Weldability 55 / 100 · Castability 40 / 100 · Brazeability / Solderability 92 / 100 · Polishability 88 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 62 MJ/kg26,655 BTU/lb · Embodied Carbon (primary production) 4 kg CO₂/kg · Embodied Water 260 L/kg31.2 gal/lb · Typical Recycled Content 45%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC23000

C23000-H02 vs C23000-H04 — frequently asked

Is C23000-H04 stronger than C23000-H02?

Yes. C23000-H04 has a typical yield strength of 360 MPa (52.2 ksi) against 275 MPa (39.9 ksi) for C23000-H02 — about 31% more. Tensile strength is 420 MPa (60.9 ksi) vs 340 MPa (49.3 ksi).

Which condition does FabDigit quote by default, H02 or H04?

OS050 is the default C23000 condition in the FabDigit quote flow (neither H02 nor H04). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C23000-H02 over C23000-H04?

Pick C23000-H02 when the part is bent, formed or impact-loaded. Pick C23000-H04 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C23000-H02 and C23000-H04 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.