FabDigitFabDigit

Copper Alloy C22600-H03 vs C22600-H08

Copper Alloy · C22600 temper comparison

C22600-H03 and C22600-H08 are two conditions of the same copper alloy grade, C22600: H03 (three-quarter hard) versus H08 (spring hard). The chemistry is identical, so every difference below comes from the condition. C22600-H08 is the stronger of the two: yield strength 483 MPa (70.1 ksi) against 359 MPa (52.1 ksi) for C22600-H03, about 35% more; tensile strength follows at 552 MPa (80.1 ksi) vs 435 MPa (63.1 ksi). In exchange, C22600-H03 is the more ductile: elongation 8% versus 3% for C22600-H08, and C22600-H08 is harder (155 HB vs 118 HB). C22600-H03 runs hotter in service (200°C vs 150°C continuous).

C22600-H03Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C22600-H08Choose it when strength drives the design.

C22600-H03 vs C22600-H08: properties

C22600-H03C22600-H08

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

435 MPa63.1 ksi
552 MPa80.1 ksi

Yield Strength (0.2% offset)

359 MPa52.1 ksi
483 MPa70.1 ksi

Elongation at Break

8%
3%

Shear Strength

283 MPa41 ksi
345 MPa50 ksi

Fatigue Strength (Endurance Limit)

170 MPa24.7 ksi
200 MPa29 ksi

Hardness, Brinell

118 HB
155 HB

Hardness, Rockwell B

67 HRB
82 HRB

Same in both: Elastic (Young's) Modulus 117 GPa17 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 118 GPa17.1 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 8.8 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,005°C1,841 °F · Liquidus Temperature 1,030°C1,886 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

200°C392 °F
150°C302 °F

Same in both: Thermal Conductivity 172 W/m·K99.4 BTU/hr·ft·°F · Specific Heat Capacity 376 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18.5 µm/m·K10.3 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

40 % IACS
38 % IACS

Same in both: Electrical Resistivity 4.3×10⁻⁸ Ω·m1.69 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.23 V · Corrosion Resistance 62 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

34 / 100
36 / 100

Formability (cold)

60 / 100
28 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 30% · Weldability 55 / 100 · Castability 35 / 100 · Brazeability / Solderability 92 / 100 · Polishability 90 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 58 MJ/kg24,936 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 290 L/kg34.7 gal/lb · Typical Recycled Content 50%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC22600

C22600-H03 vs C22600-H08 — frequently asked

Is C22600-H08 stronger than C22600-H03?

Yes. C22600-H08 has a typical yield strength of 483 MPa (70.1 ksi) against 359 MPa (52.1 ksi) for C22600-H03 — about 35% more. Tensile strength is 552 MPa (80.1 ksi) vs 435 MPa (63.1 ksi).

Which condition does FabDigit quote by default, H03 or H08?

H02 is the default C22600 condition in the FabDigit quote flow (neither H03 nor H08). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C22600-H03 over C22600-H08?

Pick C22600-H03 when the part is bent, formed or impact-loaded, or when the part sees heat. Pick C22600-H08 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C22600-H03 and C22600-H08 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.