FabDigitFabDigit

Copper Alloy C22600-H01 vs C22600-H04

Copper Alloy · C22600 temper comparison

C22600-H01 and C22600-H04 are two conditions of the same copper alloy grade, C22600: H01 (quarter hard) versus H04 (full hard). The chemistry is identical, so every difference below comes from the condition. C22600-H04 is the stronger of the two: yield strength 400 MPa (58 ksi) against 276 MPa (40 ksi) for C22600-H01, about 45% more; tensile strength follows at 462 MPa (67 ksi) vs 359 MPa (52.1 ksi). In exchange, C22600-H01 is the more ductile: elongation 25% versus 5% for C22600-H04, and C22600-H04 is harder (130 HB vs 90 HB).

C22600-H01Choose it when the part is bent, formed or impact-loaded.

C22600-H04Choose it when strength drives the design.

C22600-H01 vs C22600-H04: properties

C22600-H01C22600-H04

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

359 MPa52.1 ksi
462 MPa67 ksi

Yield Strength (0.2% offset)

276 MPa40 ksi
400 MPa58 ksi

Elongation at Break

25%
5%

Shear Strength

235 MPa34.1 ksi
300 MPa43.5 ksi

Fatigue Strength (Endurance Limit)

140 MPa20.3 ksi
180 MPa26.1 ksi

Hardness, Brinell

90 HB
130 HB

Hardness, Rockwell B

48 HRB
72 HRB

Same in both: Elastic (Young's) Modulus 117 GPa17 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 118 GPa17.1 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 8.8 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,005°C1,841 °F · Liquidus Temperature 1,030°C1,886 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 172 W/m·K99.4 BTU/hr·ft·°F · Specific Heat Capacity 376 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18.5 µm/m·K10.3 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

40 % IACS
39 % IACS

Same in both: Electrical Resistivity 4.3×10⁻⁸ Ω·m1.69 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.23 V · Corrosion Resistance 62 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

28 / 100
36 / 100

Machinability Rating (AISI 1212 = 100 %)

25%
30%

Formability (cold)

82 / 100
48 / 100

Same in both: Weldability 55 / 100 · Castability 35 / 100 · Brazeability / Solderability 92 / 100 · Polishability 90 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 58 MJ/kg24,936 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 290 L/kg34.7 gal/lb · Typical Recycled Content 50%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC22600

C22600-H01 vs C22600-H04 — frequently asked

Is C22600-H04 stronger than C22600-H01?

Yes. C22600-H04 has a typical yield strength of 400 MPa (58 ksi) against 276 MPa (40 ksi) for C22600-H01 — about 45% more. Tensile strength is 462 MPa (67 ksi) vs 359 MPa (52.1 ksi).

Which condition does FabDigit quote by default, H01 or H04?

H02 is the default C22600 condition in the FabDigit quote flow (neither H01 nor H04). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C22600-H01 or C22600-H04?

C22600-H04. Its machinability rates fair (36/100) against poor (28/100) for C22600-H01.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C22600-H01 and C22600-H04 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.