FabDigitFabDigit

Copper Alloy C19700-H01 vs C19700-H08

Copper Alloy · C19700 temper comparison

C19700-H01 and C19700-H08 are two conditions of the same copper alloy grade, C19700: H01 (quarter hard) versus H08 (spring hard). The chemistry is identical, so every difference below comes from the condition. C19700-H08 is the stronger of the two: yield strength 455 MPa (66 ksi) against 250 MPa (36.3 ksi) for C19700-H01, about 82% more; tensile strength follows at 480 MPa (69.6 ksi) vs 315 MPa (45.7 ksi). In exchange, C19700-H01 is the more ductile: elongation 18% versus 3% for C19700-H08, and C19700-H08 is harder (152 HV vs 100 HV).

C19700-H01Choose it when the part is bent, formed or impact-loaded.

C19700-H08Choose it when strength drives the design.

C19700-H01 vs C19700-H08: properties

C19700-H01C19700-H08

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

315 MPa45.7 ksi
480 MPa69.6 ksi

Yield Strength (0.2% offset)

250 MPa36.3 ksi
455 MPa66 ksi

Elongation at Break

18%
3%

Shear Strength

200 MPa29 ksi
285 MPa41.3 ksi

Fatigue Strength (Endurance Limit)

140 MPa20.3 ksi
185 MPa26.8 ksi

Hardness, Rockwell B

58 HRB
82 HRB

Hardness, Vickers

100 HV
152 HV

Same in both: Elastic (Young's) Modulus 120 GPa17.4 Msi · Shear Modulus 45 GPa6.5 Msi · Bulk Modulus 138 GPa20 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 8.89 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,075°C1,967 °F · Liquidus Temperature 1,085°C1,985 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

324 W/m·K187 BTU/hr·ft·°F
315 W/m·K182 BTU/hr·ft·°F

Max Service Temperature (continuous)

175°C347 °F
185°C365 °F

Same in both: Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.6 µm/m·K9.8 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

81 % IACS
79 % IACS

Electrical Resistivity

2.13×10⁻⁸ Ω·m0.839 µΩ·in
2.18×10⁻⁸ Ω·m0.858 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.3 V · Corrosion Resistance 58 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

28 / 100
34 / 100

Formability (cold)

75 / 100
38 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 20% · Weldability 45 / 100 · Brazeability / Solderability 95 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 57 MJ/kg24,506 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 260 L/kg31.2 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC19700

C19700-H01 vs C19700-H08 — frequently asked

Is C19700-H08 stronger than C19700-H01?

Yes. C19700-H08 has a typical yield strength of 455 MPa (66 ksi) against 250 MPa (36.3 ksi) for C19700-H01 — about 82% more. Tensile strength is 480 MPa (69.6 ksi) vs 315 MPa (45.7 ksi).

Which condition does FabDigit quote by default, H01 or H08?

H04 is the default C19700 condition in the FabDigit quote flow (neither H01 nor H08). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C19700-H01 or C19700-H08?

C19700-H08, by a small margin. Both rate poor for machinability — 34/100 against 28/100 for C19700-H01.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C19700-H01 and C19700-H08 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.