FabDigitFabDigit

Copper Alloy C19020-H04 vs C19020-O60

Copper Alloy · C19020 temper comparison

C19020-H04 and C19020-O60 are two conditions of the same copper alloy grade, C19020: H04 (full hard) versus O60 (soft annealed). The chemistry is identical, so every difference below comes from the condition. C19020-H04 is the stronger of the two: yield strength 465 MPa (67.4 ksi) against 140 MPa (20.3 ksi) for C19020-O60, about 3.3 times as much; tensile strength follows at 500 MPa (72.5 ksi) vs 320 MPa (46.4 ksi). In exchange, C19020-O60 is the more ductile: elongation 32% versus 6% for C19020-H04, and C19020-H04 is harder (152 HV vs 95 HV). C19020-O60 runs hotter in service (200°C vs 120°C continuous). On the shop floor, C19020-H04 machines more easily (32 vs 22 out of 100).

C19020-H04Choose it when strength drives the design, or when the part is machined in volume.

C19020-O60Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C19020-H04 vs C19020-O60: properties

C19020-H04C19020-O60

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

500 MPa72.5 ksi
320 MPa46.4 ksi

Yield Strength (0.2% offset)

465 MPa67.4 ksi
140 MPa20.3 ksi

Elongation at Break

6%
32%

Shear Strength

315 MPa45.7 ksi
330 MPa47.9 ksi

Fatigue Strength (Endurance Limit)

220 MPa31.9 ksi
230 MPa33.4 ksi

Hardness, Brinell

145 HB
152 HB

Hardness, Rockwell B

80 HRB
52 HRB

Hardness, Vickers

152 HV
95 HV

Same in both: Elastic (Young's) Modulus 125 GPa18.1 Msi · Shear Modulus 47 GPa6.8 Msi · Bulk Modulus 138 GPa20 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 8.9 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,065°C1,949 °F · Liquidus Temperature 1,085°C1,985 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

165 W/m·K95.3 BTU/hr·ft·°F
170 W/m·K98.2 BTU/hr·ft·°F

Max Service Temperature (continuous)

120°C248 °F
200°C392 °F

Same in both: Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.6 µm/m·K9.8 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

41 % IACS
42 % IACS

Electrical Resistivity

4.2×10⁻⁸ Ω·m1.65 µΩ·in
3.83×10⁻⁸ Ω·m1.51 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.2 V · Corrosion Resistance 62 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

32 / 100
22 / 100

Formability (cold)

55 / 100
88 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 20% · Weldability 45 / 100 · Brazeability / Solderability 90 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 57 MJ/kg24,506 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC19020

C19020-H04 vs C19020-O60 — frequently asked

Is C19020-H04 stronger than C19020-O60?

Yes. C19020-H04 has a typical yield strength of 465 MPa (67.4 ksi) against 140 MPa (20.3 ksi) for C19020-O60 — about 3.3 times as much. Tensile strength is 500 MPa (72.5 ksi) vs 320 MPa (46.4 ksi).

Which condition does FabDigit quote by default, H04 or O60?

HR04 is the default C19020 condition in the FabDigit quote flow (neither H04 nor O60). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C19020-H04 or C19020-O60?

C19020-H04, by a small margin. Both rate poor for machinability — 32/100 against 22/100 for C19020-O60.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C19020-H04 and C19020-O60 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.